absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Voltage applied to disabled output (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
NOTE 1: These ratings apply except for programming pins during a programming cycle.
recommended operating conditions
VCC
VIH
VIL
IOH
IOL
fclock†
Supply voltage
High-level input voltage
Low-level input voltage
High-level output current
Low-level output current
Clock frequency
tw†
Pulse duration, clock
tsu†
Setup time, input or feedback before clock↑
th†
Hold time, input or feedback after clock↑
TA
Operating free-air temperature
† fclock, tw, tsu, and th do not apply for TIBPAL20L8’.
High
Low
MIN NOM MAX UNIT
4.5
5 5.5 V
2
5.5 V
0.8 V
– 2 mA
12 mA
0
41.6 MHz
12
ns
12
20
ns
0
ns
–55
25 125 °C