English
Language : 

PCA6107 Datasheet, PDF (11/24 Pages) Texas Instruments – REMOTE 8-BIT I2C AND SMBus LOW-POWER I/O EXPANDER WITH INTERRUPT OUTPUT, RESET, AND CONFIGURATION REGISTERS
www.ti.com
PCA6107
REMOTE 8-BIT I2C AND SMBus LOW-POWER I/O EXPANDER
WITH INTERRUPT OUTPUT, RESET, AND CONFIGURATION REGISTERS
SCPS139B – JANUARY 2006 – REVISED OCTOBER 2006
Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
VCC
Supply voltage range
VI
Input voltage range(2)
VO
Output voltage range(2)
IIK
Input clamp current
IOK
Output clamp current
IIOK
Input/output clamp current
IOL
Continuous output low current
IOH
Continuous output high current, P7–P1
Continuous current through GND
ICC
Continuous current through VCC
θJA
Package thermal impedance(3)
Tstg
Storage temperature range
VI < 0
VO < 0
VO < 0 or VO > VCC
VO = 0 to VCC
VO = 0 to VCC
MIN
MAX UNIT
–0.5
6V
–0.5
6V
–0.5
6V
–20 mA
–20 mA
±20 mA
50 mA
–50 mA
–200
mA
160
73 °C/W
–65
150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions
VCC
Supply voltage
VIH
High-level input voltage
VIL
Low-level input voltage
IOH
High-level output current
IOL
Low-level output current
TA
Operating free-air temperature
SCL, SDA
A2–A0, P7–P0, RESET
SCL, SDA
A2–A0, P7–P0, RESET
P7-P1
P7-P0
MIN
2.3
0.7 × VCC
2
–0.5
–0.5
–40
MAX
5.5
5.5
5.5
0.3 × VCC
0.8
–10
25
85
UNIT
V
V
V
mA
mA
°C
Submit Documentation Feedback
11