English
Language : 

BQ3055 Datasheet, PDF (11/23 Pages) Texas Instruments – 2-Series, 3-Series, and 4-Series Li-Ion Battery Pack Manager
bq3055
www.ti.com
SLUSA91A – OCTOBER 2010 – REVISED JANUARY 2012
ELECTRICAL CHARACTERISTICS: OCD Current Protection
Typical values stated where TA = 25ºC and VCC = 14.4 V, Min/Max values stated where TA= –40ºC to 85ºC and VCC = 3.8 V
to 25 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V(OCD)
OCD detection threshold voltage RSNS = 0
range, typical
RSNS = 1
50
200
mV
25
100
mV
ΔV(OCDT)
OCD detection threshold voltage RSNS = 0
program step
RSNS = 1
10
mV
5
mV
V(OFFSET)
OCD offset
–10
V(Scale_Err)
OCD scale error
–10
t(OCDD)
Over Current in Discharge Delay
1
t(OCDD_STEP) OCDD Step options
2
t(DETECT)
Current fault detect time
VSRP – SRN = VTHRESH + 12.5 mV
tACC
Over Current and Short Circuit
delay time accuracy
Accuracy of typical delay time
–20
10
mV
10
%
31
ms
ms
160
µs
20
%
ELECTRICAL CHARACTERISTICS: SCD1 Current Protection
Typical values stated where TA = 25ºC and VCC = 14.4 V, Min/Max values stated where TA= –40ºC to 85ºC and VCC = 3.8 V
to 25 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V(SDC1)
SCD1 detection threshold
voltage range, typical
RSNS = 0
RSNS = 1
100
450
mV
50
225
mV
ΔV(SCD1T)
SCD1 detection threshold
voltage program step
RSNS = 0
RSNS = 1
50
mV
25
mV
V(OFFSET)
SCD1 offset
–10
V(Scale_Err)
SCD1 scale error
–10
AFE.STATE_CNTL[SCDDx2] = 0
0
t(SCD1D)
Short Circuit in Discharge Delay
AFE.STATE_CNTL[SCDDx2] = 1
0
10
mV
10
%
915
µs
1830
µs
AFE.STATE_CNTL[SCDDx2] = 0
61
µs
t(SCD1D_STEP) SCD1D Step options
AFE.STATE_CNTL[SCDDx2] = 1
122
µs
t(DETECT)
tACC
Current fault detect time
VSRP – SRN = VTHRESH + 12.5 mV
Over Current and Short Circuit
delay time accuracy
Accuracy of typical delay time
–20
160
µs
20
%
ELECTRICAL CHARACTERISTICS: SCD2 Current Protection
Typical values stated where TA = 25ºC and VCC = 14.4 V, Min/Max values stated where TA= –40ºC to 85ºC and VCC = 3.8 V
to 25 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V(SDC2)
SCD2 detection threshold
voltage range, typical
RSNS = 0
RSNS = 1
100
450
mV
50
225
mV
ΔV(SCD2T)
SCD2 detection threshold
voltage program step
RSNS = 0
RSNS = 1
50
mV
25
mV
V(OFFSET)
SCD2 offset
–10
V(Scale_Err)
SCD2 scale error
–10
AFE.STATE_CNTL[SCDDx2] = 0
0
t(SCD1D)
Short Circuit in Discharge Delay
AFE.STATE_CNTL[SCDDx2] = 1
0
10
mV
10
%
458
µs
915
µs
AFE.STATE_CNTL[SCDDx2] = 0
30.5
µs
t(SCD2D_STEP) SCD2D Step options
AFE.STATE_CNTL[SCDDx2] = 1
61
µs
t(DETECT)
tACC
Current fault detect time
VSRP – SRN = VTHRESH + 12.5 mV
Over Current and Short Circuit
delay time accuracy
Accuracy of typical delay time
–20
160
µs
20
%
Copyright © 2010–2012, Texas Instruments Incorporated
Product Folder Link(s): bq3055
Submit Documentation Feedback
11