English
Language : 

SN74ALVCH32501 Datasheet, PDF (10/11 Pages) Texas Instruments – 36-BIT UNIVERSAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
SN74ALVCH32501
36-BIT UNIVERSAL BUS TRANSCEIVER
WITH 3-STATE OUTPUTS
SCES144C – OCTOBER 1998 – REVISED MAY 2000
PARAMETER MEASUREMENT INFORMATION
VCC = 2.7 V AND 3.3 V ± 0.3 V
From Output
Under Test
CL = 50 pF
(see Note A)
500 Ω
500 Ω
6V
S1
Open
GND
TEST
tpd
tPLZ/tPZL
tPHZ/tPZH
S1
Open
6V
GND
LOAD CIRCUIT
Timing
Input
Data
Input
1.5 V
tsu
1.5 V
th
1.5 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
2.7 V
0V
2.7 V
0V
Input
1.5 V
1.5 V
2.7 V
0V
tPLH
Output
1.5 V
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
tPHL
VOH
1.5 V
VOL
Input
tw
1.5 V
1.5 V
VOLTAGE WAVEFORMS
PULSE DURATION
2.7 V
0V
Output
Control
(low-level
enabling)
1.5 V
1.5 V
2.7 V
0V
tPZL
tPLZ
Output
Waveform 1
S1 at 6 V
(see Note B)
1.5 V
3V
VOL + 0.3 V
VOL
tPZH
tPHZ
Output
Waveform 2
S1 at GND
(see Note B)
1.5 V
VOH
VOH – 0.3 V
0V
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns.
D. The outputs are measured one at a time with one transition per measurement.
E. tPLZ and tPHZ are the same as tdis.
F. tPZL and tPZH are the same as ten.
G. tPLH and tPHL are the same as tpd.
Figure 3. Load Circuit and Voltage Waveforms
10
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265