English
Language : 

TPIC46L01 Datasheet, PDF (1/19 Pages) Texas Instruments – 6-CHANNEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER
TPIC46L01, TPIC46L02, TPIC46L03
6-CHANNEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER
D 6-Channel Serial-in/Parallel-in Low-side
Pre-FET Driver
D Device Can Be Cascaded
D Internal 55-V Inductive Load Clamp and
VGS Protection Clamp for External Power
FETs
D Independent Shorted-Load/Short-to-Battery
Fault Detection on All Drain Terminals
D Independent Off-State Open-Load Fault
Sense
D Over-Battery-Voltage Lockout Protection
and Fault Reporting
D Under-Battery-Voltage Lockout Protection
for TPIC46L01 and TPIC46L02
D Asynchronous Open-Drain Fault Flag
D Device Output Can be Wire-ORed with
Multiple External Devices
D Fault Status Returned Through Serial
Output Terminal
D Internal Global Power-on Reset of Device
D High-Impedance CMOS Compatible Inputs
With Hysteresis
D TPIC46L01 and TPIC46L03 Disables the
Gate Output When a Shorted-Load Fault
Occurs
D TPIC46L02 Transitions the Gate Output to a
Low-Duty-Cycle PWM Mode When a
Shorted-Load Fault Occurs
SLIS055A – NOVEMBER 1996 - REVISED SEPTEMBER 1997
DB PACKAGE
(TOP VIEW)
FLT 1
VCOMPEN 2
VCOMP 3
IN0 4
IN1 5
IN2 6
IN3 7
IN4 8
IN5 9
CS 10
SDO 11
SDI 12
SCLK 13
VCC 14
28 VBAT
27 GATE0
26 DRAIN0
25 GATE1
24 DRAIN1
23 DRAIN2
22 GATE2
21 GATE3
20 DRAIN3
19 DRAIN4
18 GATE4
17 DRAIN5
16 GATE5
15 GND
description
The TPIC46L01, TPIC46L02, and TPIC46L03 are low-side predrivers that provide serial input interface and
parallel input interface to control six external field-effect transistor(FET) power switches such as offered in the
TI TPIC family of power arrays. These devices are designed primarily for low-frequency switching, inductive
load applications such as solenoids and relays. Fault status for each channel is available in a serial-data format.
Each driver channel has independent off-state open-load detection and on-state shorted-load/short-to-battery
detection. Battery overvoltage and undervoltage detection and shutdown are provided. Battery and output load
faults provide real-time fault reporting to the controller. Each channel also provides inductive-voltage-transient
protection for the external FET.
These devices provide control of output channels through a serial input interface or a parallel input interface.
A command to enable the output from either interface enables the respective channel GATE output to the
external FET. The serial input interface is recommended when the number of signals between the control device
and the predriver must be minimized, and the speed of operation is not critical. In applications where the
predriver must respond very quickly or asynchronously, the parallel input interface is recommended.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Copyright © 1997, Texas Instruments Incorporated
1