Y_DEG0 (0x18)
This register holds the constant compensation factor for the RTC temperature compensation. One LSB is equivalent to
0.1PPM.
Bits 31-16: These bits (Y_CALC0) represent the constant compensation factor.
Y_DEG1_2 (0x19)
This register holds the linear and quadratic compensation factors for the RTC temperature compensation.
31
16
Y_CALC1 = linear compensation factor. One LSB is equi-
valent to 0.01PPM/°
15
0
Y_CALC2 = quadratic compensation factor. One LSB is
equivalent to 0.001PPM/°C
Both Y_DEG0 and Y_DEG1_2 can be used to compensate the RTC to be accurate over the whole temperature range by
characterizing the crystal.
Registers for Output Signals
PULSEW_R_CNTS (0x41)
This register contains the pulse count for the PULSEW and PULSER output pins for the past accumulation interval. The
counters will be cleared at the beginning of each accumulation interval and then start counting up with each generated pulse.
Bit 15-0: The counter for the PULSER (VARh) generator.
Bit 31-16: The counter for the PULSEW (Wh) generator.
31
Counter for the PULSEW generator (Wh)
16 15
0
Counter for the PULSER generator (VARh)
At pulse rates that do not result in generation of whole counts per accumulation interval, e.g. 3 1/3 pulses, the count equivalent
to the next lower natural number will be generated until the residue accumulates to a full count, i.e. the pulse sequence
generated will be 3, 3, 3, 4, 3, 3, 3, 4…
PULSE3_4_CNTS (0x42)
This register contains the pulse count for the PULSE3 and PULSE4 output pins for the accumulation interval. The counters
will be cleared at the beginning of each accumulation interval and then start counting up with each generated pulse.
Bit 15-0: The counter for the PULSE4 generator.
Bit 31-16: The counter for the PULSE3 generator.
31
16 15
0
Counter for the PULSE3 generator
Counter for the PULSE4 generator
IASQSUM (0x39), IBSQSUM (0x3A), ICSQSUM (0x3B)
These registers hold the sum of the squared current samples collected during the previous accumulation interval. The
values for IASQSUM, IBSQSUM, and ICSQSUM are provided directly by the CE and are not post-processed. The magnitude
of the accumulated samples is determined by:
LSB = IMAX 2 9.4045 ⋅10−13 A2 h
In _ 82
Page: 40 of 57
© 2005-2008 TERIDIAN Semiconductor Corporation
V1.4