English
Language : 

SS24D50 Datasheet, PDF (4/4 Pages) Teledyne Technologies Incorporated – Output to 75A, 510 Vac Solid-State Relay with Diagnostic
Control
0
1
Control LED
0
1
0
0
1
1
Mains
No
No
Yes
Yes
Yes
Yes
Yes
Yes
NEW Series SS
Output to 75A, 510 Vac
Solid-State Relay with Diagnostic
DIAGNOSTIC DESCRIPTION
Load
X
X
SSR
X
X
Output LED
Output
Status
Open
Open
OK
OK
OK
OK
Closed
Closed
Open
OK
Open
OK
OK
Short circuit
OK
Short circuit
Figure 6
Open
Open
Open
Open
• The yellow LED luminosity
depends on:
– Load voltage.
– Control: ON or OFF.
– Load type.
• The status outputs can be
connected in series.
• NPN or PNP output is possible
with status.
• Mains voltage lower than
specifications (150 Vac). The
SSR works correctly, but an
alarm status can be given
without control.
Mains
OPEN MAINS
DIAGNOSTIC OVERVIEW
On
Control
Off
Current
ton
Open
Status
output
Closed
to1
tc1
to1
to2
to2
OPEN LOAD
toff
tc2
to1
to2
Figure 7
TIMING SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
Min Max Units
t01 – Open Delay (Typical)
70
ms
t02 – Open Time (Typical)
120
ms
tc1 – Close Time
20
ms
tc2 – Close Time
20
ms
SHORT CIRCUIT
ON OUTPUT
tc1
• Output status is normally closed
without failure on the relay and
the load. The output LED is
normally ON.
• In case of failure on the load
(open) or on the SSR (short-
circuit condition):
- the status is open
- the output LED is switched OFF
Important: If you use a long
wiring cable between the SSR
and the load (>25 meters), the
diagnostic system might not be
able to detect an open load.
Control LED
Output LED
NOTES
1. For additional/custom options, contact factory.
SS Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS
SS\052003\Q1