English
Language : 

E3P48R50-16 Datasheet, PDF (4/4 Pages) Teledyne Technologies Incorporated – Three-Phase Output to 75A 600 Vac DC Control
Series E3P
THERMAL CHARACTERISTICS
60
50
40
Full on-state
30
0.95°C/W
1.2°C/W
3°C/W
20
Without heat sink
10
0
0
110
100
90
80
70
60
50
40
30
20
10
0
0
2 4 6 8 10
Load Current (Arms)
12 0 10 20 30 40 50 60 70 80 90 100
Ambient Temperature (°C)
Figure 5a — 12A output
Full on-state
0.55°C/W
0.9°C/W
1.2°C/W
Without heat sink
5
10 15 20
Load Current (Arms)
25 0 10 20 30 40 50 60 70 80 90 100
Ambient Temperature (°C)
Figure 5b — 25A output
220
Full on-state
200
0.3°C/W
180
160
.55°C/W
140
120
.95°C/W
100
1.2°C/W
80
60
50% duty cycle
40
(R type only)
20
Without heat sink
0
0 5 10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60 70 80 90 100
Load Current (Arms)
Ambient Temperature (°C)
Figure 5c — 50A output
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
Full on-state
0.3°C/W
0.55°C/W
0.95°C/W
1.2°C/W
Without heat sink
10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 90 100
Load Current (Arms)
Ambient Temperature (°C)
Figure 5d — 75A output
SURGE CURRENT
150
Non-Repetitive
100
50
Repetitive with initial Tj = 70°C
0
0.01
0.1
1
10
t(s)
Figure 6a — 12A output
250
200
Non-Repetitive
150
100
50
Repetitive with initial Tj = 70°C
0
0.01
0.1
1
10
t(s)
Figure 6b — 25A output
600
400
Non-Repetitive
200
Repetitive with initial Tj = 70°C
0
0.01
0.1
1
10
t (s)
Figure 6c — 50A output
1500
1000
Non-Repetitive
500
Repetitive with initial Tj = 70°C
0
0.01
0.1
1
10
t (s)
Figure 6d — 75A output
NOTES:
1. Electrical specifications at 25°C unless otherwise specified.
2. For 800Hz applications, contact factory.
3. For additional/custom options, contact factory.
E3P 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS
E3P\032003\Q1