English
Language : 

E3P48R50-16 Datasheet, PDF (3/4 Pages) Teledyne Technologies Incorporated – Three-Phase Output to 75A 600 Vac DC Control
Series E3P
OUTPUT (LOAD) SPECIFICATION
Min
Max
Operating Range
E3P48XXX-16
24
520
E3P48
24
600
Units
Vrms
Vrms
Peak Voltage
All relays
1200 Vpeak
Load Current Range
12A output current
.005
25A output current
.005
50A output current
.005
75A output current
.005
12
A
25
A
50
A
75
A
Inductive Load Current
E3P with -16 option 50A output
E3P with -16 option 75A output
12 Arms
16 Arms
Maximum Surge Current Rating (Non-Repetitive)
12A output
120
A
25A output
230
A
50A output
550
A
75A output
1000 A
On-State Voltage Drop
All relays output current
1.4
V
Zero Cross Window (Typical)
E3P48DXX-16
E3P48
E3P48R
12
V
24
V
NA
Off-State Leakage Current (60Hz)
E3P48DXX-16
All other relays
5
mA
1
mA
Turn-On Time (60 Hz)
E3P48R
All other relays
0.1
ms
8.3
ms
Turn-Off Time (60 Hz)
All relays
8.3
ms
OUTPUT (LOAD) SPECIFICATION (Continued)
Min
Max Units
Off-State dv/dt
All relays
500 V/µs
Maximum di/dt (Non-Repetitive)
All relays
50 A/µs
Operating Frequency Range
All relays
10
440 Hz
I2t for Match Fusing (<8.3ms)
12A output
25A output
50A output
75A output
72
A2S
265 A2S
1500 A2S
5000 A2S
ENVIRONMENTAL SPECIFICATION
Min
Max Units
Operating Temperature
–40
100
°C
Storage Temperature
–40
100
°C
Input-Output Isolation
4000
Vrms
Output-Case Isolation
E3P48D12
2500
Vrms
E3P48D25
2500
Vrms
All other relays
3300
Vrms
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
E3P 3
E3P\032003\Q1