English
Language : 

J114D-26M Datasheet, PDF (2/6 Pages) Teledyne Technologies Incorporated – CENTIGRID ESTABLISHED RELIABILITY RELAYS
SERIES 114
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
Contact Arrangement
Rated Duty
Contact Resistance
Contact Load Ratings (DC)
(See Fig. 2 for other DC
resistive voltage/current ratings)
Contact Load Ratings (AC)
Contact Life Ratings
Contact Overload Rating
Contact Carry Rating
Operate Time
Release Time
Contact Bounce
Intercontact Capacitance
Insulation Resistance
Dielectric Strength
Negative Coil Transient (Vdc)
Diode P.I.V. (Vdc)
2 Form C (DPDT)
Continuous
0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header)
Resistive:
Inductive:
Lamp:
Low Level:
1 Amp/28Vdc
200 mA/28Vdc (320 mH)
100 mA/28Vdc
10 to 50 μA/10 to 50mV
Resistive:
250 mA/115Vac, 60 and 400 Hz (Case not grounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
2A/28Vdc Resistive (100 cycles min.)
Contact factory
2.0 msec max. at nominal rated coil voltage
114 Series: 1.5 msec max. 114D, 114DD Series: 4.0 msec max.
1.5 msec max.
0.4 pf typical
10,000 megohms min. between mutually isolated terminals
Atmospheric pressure: 500 Vrms/60Hz
70,000 ft.: 125 Vrms/60Hz
114D, 114DD
1.0 max
114D, 114DD
100 min.
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
BASE PART
NUMBERS
(See Note 8 for full P/N example)
Coil Voltage (Vdc)
Coil Resistance
(Ohms ±10% @25°C)
Coil Current (mAdc @25°C)
(114DD Series)
Pick-up Voltage (Vdc, Max.)
Drop-out Voltage (Vdc)
Nom.
Max.
114, 114D
114DD (Note 4)
Min.
Max.
114, 114D
114DD
114, 114D
Min.
Max.
114DD
Min.
Max.
114-5
114D-5
114DD-5
5.0
5.8
50
39
93.2
128.2
3.5
4.0
0.14
2.3
0.6
2.8
114-6
114D-6
114DD-6
6.0
8.0
98
78
58.3
78.3
4.5
5.0
0.18
3.2
0.7
3.4
114-9
114-12 114-18 114-26
114D-9 114D-12 114D-18 114D-26
114DD-9 114DD-12 114DD-18 114DD-26
9.0
12.0
18.0
26.5
12.0
16.0
24.0
32.0
220
390
880
1560
220
390
880
1560
33.0
25.6
17.5
14.8
42.9
32.8
22.1
18.5
6.8
9.0
13.5
18.0
7.8
10.0
14.5
19.0
0.35
0.41
0.59
0.89
4.9
6.5
10.0
13.0
0.8
0.9
1.1
1.4
5.3
6.5
10.0
13.0
PERFORMANCE CURVES
(NOTE 2)
TYPICAL RF PERFORMANCE
0
.1
.2
.3
.4
10
20
30
40
50
60
70
.01
INSERTION LOSS
IRSOETLAUTIRSIONONLLAOATSCIOSRNO(VSASSCWRCROO)SNSTAPCOTLSES
1.92
1.22
1.07
1.02
1.01
1.00
0.5 .1
1.00
.5 1.0
FREQUENCY (GHz)
FIGURE 1
TYPICAL DC CONTACT RATING (RESISTIVE)
300
250
200
150
100
50
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LOAD CURRENT (AMPS DC)
FIGURE 2
114 Page 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2006 TELEDYNE RELAYS
114/0706/Q1