English
Language : 

AC4088 Datasheet, PDF (2/2 Pages) Teledyne Technologies Incorporated – 800 TO 4000 MHz TO-8 CASCADABLE AMPLIFIER
AC4088
TYPICAL PERFORMANCE
KEY: +25 °C
+85 °C
Gain vs Temperature Vcc = 15
-55 °C
22.0
21.0
20.0
19.0
18.0
17.0
0.5 .75 0.8 1.0
2.0
2.5
3.0
3.5
4.0 4.2
FREQUENCY - GHz
Noise Figure Vcc = 15 & 12
5.0
4.0
3.0
2.0
0.5 .75 0.8 1.0
2.0
2.5
3.0
3.5
4.0 4.2
FREQUENCY - GHz
Power Output at 1 dB Compression
23.0
22.0
+15 V
21.0
20.0
+12 V
19.0
18.0
17.0
0.5 .75 0.8 1.0
2.0
2.5
3.0
3.5
FREQUENCY - GHz
4.0 4.2
Intercept Point Vcc = 15
70
2nd HAR
60
50
IP2
40
IP3
30
20
0.5 .75 0.8 1.0
2.0
2.5
3.0
3.5
FREQUENCY - GHz
4.0 4.2
Intercept Point Vcc = 12
70
2nd HAR
60
50
40
30
IP3
20
10
0.5 .75 0.8 1.0
2.0
2.5
3.0
FREQUENCY - GHz
IP2
3.5
4.0 4.2
TYPICAL AUTOMATIC TEST DATA
Model: AC4088
FREQ SWR SWR
MHZ
IN
OUT
500
1.49
1.25
700
1.23
1.09
900
1.11
1.02
1000
1.09
1.03
1200
1.12
1.05
1400
1.19
1.04
1600
1.26
1.05
1800
1.31
1.04
2000
1.38
1.07
2200
1.44
1.11
2400
1.45
1.15
2600
1.40
1.23
2800
1.39
1.35
3000
1.37
1.43
3200
1.35
1.52
3400
1.30
1.54
3600
1.25
1.56
3800
1.23
1.61
4000
1.23
1.50
4200
1.23
1.40
Vcc= +15V
GAIN
PHASE
DB
DEG
19.70
3
20.18
-35
20.34
-66
20.43
-80
20.54
-107
20.40
-133
20.46
-158
20.35
178
20.11
154
19.95
131
19.76
110
19.72
88
19.91
66
19.98
44
20.27
19
20.62
-5
20.70
-31
20.64
-59
20.32
-89
19.54
-120
DELAY
NSEC
0.69
0.49
0.41
0.39
0.37
0.34
0.35
0.34
0.33
0.32
0.30
0.30
0.30
0.31
0.37
0.37
0.36
0.40
0.41
0.44
LINEAR S-PARAMETERS
Model: AC4088
Vcc 15V
FREQ.
S11
S21
S12
MHz
MAG ANG MAG ANG MAG ANG
500
0.20 -120.6 9.66 2.6
0.012 19.9
700
0.10 -136.3 10.21 -35.1 0.013 3.3
900
0.05 -136.7 10.40 -66.0 0.013 -12.8
1000
0.04 -124.1 10.51 -80.0 0.013 -17.1
1200
0.06 -100.0 10.64 -107.2 0.012 -29.0
1400
0.09 -93.4 10.48 -132.9 0.012 -45.0
1600
0.12 -107.8 10.55 -157.7 0.010 -60.5
1800
0.13 -121.5 10.41 177.8 0.010 -74.4
2000
0.16 -132.8 10.13 153.9 0.009 -94.8
2200
0.18 -140.7 9.95 131.4 0.008 -113.1
2400
0.18 -147.2 9.73 109.6 0.008 -131.6
2600
0.17 -156.8 9.69 87.8 0.009 -154.0
2800
0.16 -168.3 9.90 66.4 0.010 -170.3
3000
0.16 -175.9 9.98 43.7 0.012 174.2
3200
0.15 179.9 10.32 19.2 0.012 165.3
3400
0.13 174.4 10.74 -4.8
0.014 157.0
3600
0.11 167.7 10.84 -30.7 0.016 155.2
3800
0.10 151.5 10.76 -59.4 0.018 143.6
4000
0.10 135.7 10.37 -88.7 0.019 137.5
4200
0.10 109.9
9.49 -119.9 0.020 136.0
Icc= 89.12
REV/ISO
DB
-38.3
-37.7
-37.6
-37.8
-38.4
-38.5
-40.2
-39.9
-40.9
-41.9
-41.6
-41.1
-39.6
-38.7
-38.3
-36.9
-35.7
-35.1
-34.4
-33.9
Icc= 89.12
S22
MAG ANG
0.11 76.4
0.04 53.7
0.01 161.1
0.01 -160.0
0.03 -172.8
0.02 146.7
0.02 143.7
0.02 166.0
0.03 -96.7
0.05 -76.8
0.07 -83.1
0.10 -90.2
0.15 -98.4
0.18 -104.6
0.21 -107.7
0.21 -121.7
0.22 -131.5
0.23 -135.2
0.20 -137.6
0.17 -142.7
Model: AC4088
FREQ SWR SWR
MHZ
IN
OUT
500
1.50
1.22
700
1.24
1.08
900
1.12
1.07
1000
1.11
1.08
1200
1.12
1.11
1400
1.18
1.11
1600
1.24
1.13
1800
1.29
1.12
2000
1.35
1.05
2200
1.42
1.01
2400
1.43
1.05
2600
1.40
1.12
2800
1.38
1.22
3000
1.37
1.30
3200
1.36
1.39
3400
1.30
1.40
3600
1.24
1.41
3800
1.21
1.49
4000
1.19
1.44
4200
1.19
1.39
Vcc= +12V
GAIN
PHASE
DB
DEG
19.55
2
20.05
-35
20.24
-65
20.34
-79
20.50
-106
20.38
-132
20.47
-157
20.39
179
20.17
155
20.00
132
19.84
110
19.79
88
19.93
67
20.02
44
20.32
20
20.62
-4
20.73
-30
20.67
-59
20.35
-88
19.65
-119
DELAY
NSEC
0.68
0.48
0.41
0.39
0.37
0.34
0.35
0.34
0.33
0.32
0.30
0.31
0.30
0.31
0.36
0.36
0.35
0.40
0.41
0.45
Icc= 85.41
REV/ISO
DB
-39.3
-38.2
-38.3
-38.4
-38.5
-39.0
-39.3
-41.0
-41.6
-42.1
-42.3
-41.1
-40.6
-39.2
-37.7
-36.3
-35.2
-34.5
-33.4
-33.4
650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • microwave@teledyne.com