English
Language : 

AC4088 Datasheet, PDF (1/2 Pages) Teledyne Technologies Incorporated – 800 TO 4000 MHz TO-8 CASCADABLE AMPLIFIER
Rev. 5/10
AC4088
800 TO 4000 MHz
TO-8 CASCADABLE AMPLIFIER
Typical Values
High Output Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Second Order I.P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low Noise Figure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Performance Thin Film
Standard Size TO-8 Package
AC4088
+21.5 dBm
+19.5 dB
+52 dBm
<4.3 dB
AC4088
TO-8 Package for Amplifiers
SPECIFICATIONS*
Parameter
Typical
Frequency (Min.)
800-4000 MHz
Small Signal Gain (Min.)
19.5 dB
Gain Flatness (Max.)
±0.4 dB
Noise Figure (Max.)
<4.3 dB
SWR (Max.)
Input
Output
<1.4:1
<1.6:1
Power Output (Min.)
@ 1dB comp.
+21.5 dBm
Reverse Isolation
38.0 dB
DC Current (Max.)
92 mA
Guaranteed
0 to 50 °C -55 to +85 °C
800-4000 MHz 800-4000 MHz
19.0 dB
18.5 dB
±0.7 dB
±0.9 dB
4.8 dB
5.2 dB
1.8:1
1.8:1
1.9:1
1.9:1
+20.5 dBm
—
97.0 mA
+20.0 dBm
—
103.0 mA
* Measured in a 50-ohm system at +15 Vdc unless otherwise specified.
INTERMODULATION PERFORMANCE
Typical @ 25 °C
+12 Volts
Second Order Harmonic Intercept Point . . . . . +57 dBm
Second Order Two Tone Intercept Point . . . . . . +51 dBm
Third Order Two Tone Intercept Point . . . . . . . . +33 dBm
+15 Volts
+56 dBm
+52 dBm
+34 dBm
AS4088
SMTO-8 Package for Amplifiers
ABSOLUTE MAXIMUM RATINGS
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -62 to +125 °C
Maximum Case Temperature . . . . . . . . . . . . . . . . . . . . . . . .
+105 °C
Maximum DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+17 Volts
Maximum Continuous RF Input Power . . . . . . . . . . . . . . . .
+17 dBm
Maximum Short Term Input Power (1 Minute Max.) . . . . . . . 100 Milliwatts
Maximum Peak Power (3 µsec Max.) . . . . . . . . . . . . . . . . . .
0.5 Watt
Burn-in Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+85 °C
Thermal Resistance1 (θjc) . . . . . . . . . . . . . . . . . . . . . . . . . . +41 °C/Watt
Junction Temperature Rise Above Case (Tjc) . . . . . . . . . . .
+59.4 °C
1 Thermal resistance is based on total power dissipation.
DIMENSIONS ARE IN INCHES [MILLIMETERS]
650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • microwave@teledyne.com