GPD-403/463— 5 to 400 MHz (continued)
Automatic Network Analyzer Measurements (Typical production unit @ +25°C ambient)
Numerical Readings
Bias = 24.00 Volts
FREQUENCY
MHz
100.0
150.0
200.0
250.0
300.0
350.0
400.0
450.0
500.0
550.0
600.0
650.0
700.0
750.0
800.0
VSWR
IN
1.07
1.10
1.12
1.16
1.19
1.24
1.28
1.33
1.38
1.45
1.52
1.61
1.70
1.81
1.95
GAIN
dB
10.50
10.37
10.33
10.14
10.14
10.04
9.95
9.79
9.59
9.46
9.24
9.05
8.89
8.64
8.31
PHASE
DEGREES
176.22
174.17
170.97
168.32
166.45
164.55
163.35
161.56
160.50
158.96
156.90
155.95
154.22
152.36
150.69
PHASE
DEV
.39
.56
–.40
–.83
–.47
–.13
.88
GROUP DELAY
ns
.00
.15
.16
.13
.10
.09
.08
.08
.07
.10
.08
.07
.10
.10
.08
VSWR
OUT
1.65
1.63
1.62
1.60
1.57
1.55
1.51
1.48
1.45
1.41
1.39
1.35
1.32
1.29
1.28
ISOLATION
dB
20.66
20.24
20.03
19.76
19.52
19.09
18.72
18.40
18.10
17.64
17.26
16.95
16.50
16.19
16.00
S-Parameters
FREQUENCY
MHz
100.00
150.00
200.00
250.00
300.00
350.00
400.00
450.00
500.00
550.00
600.00
650.00
700.00
750.00
800.00
S11
Mag Ang
.033 –121.8
.049 –116.6
.059 –115.5
.075 –115.0
.089 –117.5
.105 –119.1
.126 –121.5
.144 –123.9
.162 –126.4
.182 –130.4
.209 –133.6
.237 –136.8
.262 –141.5
.291 –146.6
.323 –151.3
S21
dB
Ang
10.482
10.369
10.352
10.160
10.149
10.018
9.947
9.812
9.572
9.470
9.238
9.045
8.896
8.638
8.281
176.1
174.0
171.1
168.3
166.6
164.4
163.4
161.4
160.6
158.9
156.9
155.9
154.2
152.4
150.7
S12
dB
Ang
–20.574 17.0
–20.272 24.0
–20.208 30.4
–19.797 38.1
–19.324 44.8
–19.131 51.8
–18.672 58.1
–18.416 63.5
–18.125 69.5
–17.575 74.6
–17.317 78.9
–16.391 84.5
–16.538 88.7
–16.183 93.1
–16.035 96.6
Bias = 24.00 Volts
S22
Mag Ang
.248 –11.4
.242 –16.0
.236 –20.6
.231 –26.7
.226 –31.3
.215 –37.4
.204 –43.6
.193 –50.0
.183 –56.3
.173 –63.3
.162 –70.1
.150 –76.9
.140 –82.6
.127 –89.8
.120 –96.3