GPD-402/462— 5 to 400 MHz (continued)
Automatic Network Analyzer Measurements (Typical production unit @ +25°C ambient)
S-Parameters
Bias = 15.00 Volts
FREQUENCY
MHz
S11
Mag Ang
S21
dB
Ang
S12
dB
Ang
S22
Mag Ang
100.00
150.00
200.00
250.00
300.00
350.00
400.00
450.00
500.00
550.00
600.00
650.00
700.00
750.00
800.00
.235 –179.6
.230 –178.7
.221 –177.6
.209 –173.3
.207 –168.0
.212 –160.8
.228 –154.2
.258 –148.9
.298 –146.4
.346 –145.8
.400 –147.2
.457 –150.1
.512 –154.7
.569 –159.7
.617 –164.5
14.333
14.267
14.297
14.225
14.267
14.253
14.179
14.178
13.985
13.839
13.746
13.382
13.047
12.735
12.341
174.0
170.8
167.9
163.6
160.7
156.9
154.0
150.5
146.4
142.9
138.4
133.7
130.0
126.1
121.4
–23.399 15.6
–23.288 23.6
–23.158 28.4
–22.753 36.3
–22.286 42.9
–22.099 49.7
–21.392 55.4
–21.186 58.8
–20.985 64.6
–20.484 67.1
–20.250 71.3
–20.036 75.1
–19.837 77.9
–19.672 79.9
–19.820 81.9
.183 3.2
.181 8.7
.183 11.3
.181 14.4
.185 18.2
.187 24.2
.196 29.4
.209 34.4
.231 38.2
.259 41.0
.292 41.7
.329 41.1
.366 39.4
.406 36.7
.441 32.8
GPD-403/463— 5 to 400 MHz
Typical Performance Over Temperature (@ +24 VDC unless otherwise noted)
Gain
12
11
10
9
8
5
100
200
300
400
Frequency, MHz
Noise Figure
9
Power Output
20
8
18
7
16
6
14
5
12
5
100
200
300
400
5
100
200
300
400
Frequency, MHz
Frequency, MHz
Key: +25°C
+85°C
-55°C
2.0
1.75
1.5
1.25
1.0
5
Input VSWR
100
200
300
400
Frequency, MHz
2.0
1.75
1.5
1.25
1.0
5
Output VSWR
100
200
300
400
Frequency, MHz
Third-Order Intercept Point
35
30
25
20
15
0
100
200
300
400
Frequency, MHz
Second-Order Intercept Point
55
45
35
25
15
0
100
200
300
400
Frequency, MHz