English
Language : 

TC18C46-1 Datasheet, PDF (8/10 Pages) TelCom Semiconductor, Inc – CMOS CURRENT MODE PWM CONTROLLER
TC18C46
TC28C46
TC38C46
CMOS CURRENT MODE
PWM CONTROLLERS
VDD
PIN 8
1/FO
TD
0.5V 3.5V
ICHARGE
Ï·
3.5V
RORT
8
9
10
SYNC
RT
2mA
DISCHARGE
CT
CURRENT
3.5V
TCHG
PIN 10
OUTPUT DEAD TIME (TD)
Figure 6. Oscillator Circuit
Selection of Timing Capacitor and Resistor
(CT & RT)
1) First determine the frequency of operation FO and
the desired " dead" time", TD (see Fig.6 graph).
We need to choose RT and CT.
Substituting and rearranging,
CT = TD (.002 - 3.5)
3
RT
Knowing TD choosing RT permits calculation of CT .
2) The current mirror in Fig. 6 , shows:
ICHG = 3.5 V . Also,
RT
ICHG = CT ∆V Where,
∆T
and
∆V = 3.5 - 0.5
= 3.0 Volts
∆T = TCHG
3) During discharge (TD), the discharge current pulls
2 m A out of CT, minus the ICHG that keeps trying to
charge it:
2 m A - ICHG = CT ∆V ,where ∆V= 3.0 Volts
∆T
∆T= TD
4-108
TELCOM SEMICONDUCTOR, INC.