English
Language : 

MS5541-30C Datasheet, PDF (9/19 Pages) Intersema Sensoric SA – MINIATURE 30 bar MODULE
MS5541-30C
Miniature 30 bar Module
NOTES
1) Readings of D2 can be done less frequently, but the display will be less stable in this case.
2) For a stable display of 1 mbar resolution, it is recommended to display the average of 8 subsequent
pressure values.
C1 (13 Bit)
C2/I (3 Bit)
Word 1 DB12 DB11 DB10 DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB12 DB11 DB10
C2/II (10 Bit)
C5/I (6 Bit)
Word 2
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0 DB11 DB10 DB9
DB8
DB7
DB6
C3 (10 Bit)
C5/II (6 Bit)
Word 3
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
DB5
DB4
DB3
DB2
DB1
DB0
C4 (9 Bit)
C6 (7 Bit)
Word 4
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB1
DB6
DB5
DB4
DB3
DB2
DB1
DB0
Fig. 4: Arrangement (Bit-pattern) of calibration data in Word1 to Word4
SENSOR SOLUTIONS ///MS5541-30C
09/2015