English
Language : 

7000 Datasheet, PDF (4/7 Pages) C&K Components – Miniature Toggle Switches
Specialty Relays
AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued)
Timing Specifications (All values shown are at nominal voltage and 25°C unless otherwise specified)
Minimum operating voltages are based on vertically mounted 7012 units. 7012 hori-
zontally mounted or 7022 vertically or horizontally mounted units will operate satis-
factorily at minimum voltages approximately 5% lower than those listed.
AC units drop out at approximately 50% of rated voltage. DC units drop out at approx-
imately 10% of rated voltage.
All units may be operated on intermittent duty cycles at voltages 10% above the listed
maximums (intermittent duty - maximum 50% duty cycle and 30 minutes “on” time.)
Surge/Transient Protection Option Characteristics (DC Timers Only)
Coil Voltage
Nominal (DC)
12 V
24 V
28 V
32 V
48 V
60 V
96 V
110 V
125 V
220 V
250 V
Max Excess
Energy Capacity (Joule)
0.4 J
1.8 J
1.8 J
2.5 J
3.57 J
6J
10 J
10 J
10 J
17 J
17 J
Max De-energization
Transient Voltage
48 V
93 V
93 V
135 V
145 V
250 V
340 V
340 V
340 V
366 V
366 V
Surge Life —
Applied 100,000 times continuously with the interval of 10 seconds at room tempera-
ture. Below 68 VAC: 12A; Above 68 VAC: 35A
Temperature Range —
Operating — -22°F to +167°F (-30°C to + 75°C)
Storage — -40°F to +167°F (-40°C to +75°C)
Output/Life Contact Ratings — Contact Capacity in Amps (Resistive Load)
Contact
Voltage
30 VDC
110 VDC
120 V 60Hz
240 V 60Hz
480 V 60Hz
Min. 100,000
Operations
15.0
1.0
20.0
20.0
12.0
Min. 1,000,000
Operations
7.0
0.5
15.0
15.0
10.0
10 Amps Resistive, 240 VAC
1/4 Horsepower, 120 VAC/240VAC (per pole)
15 Amps 30 VDC (per pole)
5 Amps, General Purpose, 600VAC (per pole)
Dielectric — Withstands 1500 volts RMS 60Hz between terminals and ground.
1,000 volts RMS 60 Hz between non-connected terminals. For dielectric specification
on hermetically sealed models consult factory.
Insulation Resistance — 500 Megohms with 500VDC applied.
Temperature Range —
Operating — -20°F to +165°F (-29°C to 74°C)
Storage — -67°F to +165°F (-55°C to 74°C)
Temperature Variation — Using a fixed time delay which was set and measured
when the ambient temperature was 77°F (25°C), the maximum observed shift in the
average of three consecutive time delays was -20% at -20°F (-29°C) and +20% at
165°F (74°C).
Mounting/Terminals — Normal mounting of the basic unit is in a vertical position,
from the back of the panel. All units are tested for vertical operation. Basic
models (7012, 7022) may also be horizontally mounted, and will be adjusted accord-
ingly when Accessory Y1 is specified in your order.
Standard screw terminals (8-32 truss head screws supplied) are located on the front of
the unit, with permanent schematic markings. Barrier isolation is designed to accom-
modate spade or ring tongue terminals, with spacing to meet all industrial control
specifications.
The basic Series 7000 may also be panel mounted with the addition of a panel mount
kit, X option, that includes all necessary hardware and faceplate. This offers the
convenience of “out-front” adjustment, with large dial skirt knob. The faceplate and
knob blend with advanced equipment and console designs, while the body of the unit
and its wiring are protected behind the panel.
Other mounting options include plug-in styles and special configurations to meet
unusual installation requirements. Contact factory for details.
Power Consumption — Approximately 8 watts power at rated voltage .
Approximate Weights —
Models
7012, 7022 . . . . . . . . . . . . . . . . . . . . . . . 2 lbs. 4 ozs.
7014, 7024 . . . . . . . . . . . . . . . . . . . . . . 2 lbs. 10 ozs.
7032 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 lbs. 5 ozs.
Weight may vary slightly with coil voltage.
12
Catalog 5-1773450-5
Revised 3-13
www.te.com
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Dimensions are in millimeters USA: +1 800 522 6752
unless otherwise specified. Asia Pacific: +86 0 400 820 6015
UK: +44 800 267 666
For additional support numbers
please visit www.te.com
12–11