English
Language : 

7000 Datasheet, PDF (3/7 Pages) C&K Components – Miniature Toggle Switches
Specialty Relays
AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued)
Surge/Transient Protection Option
Product Facts
Transient Suppressor
Option "V"
n Protect electronic control
circuits from voltage
transients generated by the
timer coil
n Fast response to the rapidly
rising back E.M.F.
n High performance clamping
voltage characteristics
n UL recognized, (except
varistor and coil together).
n Timer NOT polarity sensitive
The Surge/Transient Protection Option protects electronic
control circuits from transients and surges which are
generated when the timer coil is activated. The device is not
polarity sensitive and permits the user to initiate, delay,
sequence and program equipment actions over a wide range
of applications under the most severe operating conditions.
The varistor will not affect the operating characteristics of
the 7000 Timer. The varistor has bilateral and symmetrical
voltage and current characteristics.
Timing Specifications (All values shown are at nominal voltage and 25°C unless otherwise specified)
Operating Modes —
Model 7012/7014 — On-delay (delay on pick-up).
Model 7022/7024 — Off-delay (delay on drop-out).
Model 7032 — On-delay, off-delay (double head).
Timing Adjustment — Timing is set by simply turning the dial to the desired time
value. In the zone of approximately 25° separating the high and low end of timing
ranges A,D,E, and K, instantaneous operation (no time delay) will occur. All other
ranges produce an infinite time delay when the dial is set in this zone.
Models 7014 and 7032 are available with letter dials only. The upper end of the time
ranges in these models may be twice the values shown.
Linear Timing Ranges —
Code
A
B
C
D
E
F
H
I
J
K
Models 7012,
7022, 7024
.1 to 1 Sec.
.5 to 5 Sec.
1.5 to 15 Sec
5 to 50 Sec.
20 to 200 Sec.
1 to 10 Min.
3 to 30 Min.
6 to 60 Min.
3 to 120 Cyc.
1 to 300 Sec.
Models 7014,
7032
.2 to 2 Sec.
.7 to 7 Sec.
2 to 20 Sec.
10 to 100 Sec.
30 to 300 Sec.
1.5 to 15 Min.
3 to 30 Min.
Not Avail.
Not Avail.
Not Avail.
Repeat Accuracy —
For delays of 200 seconds or less:
For delays greater than 200 seconds:
7012*, 7022, 7024:
7014*:
7032:
7012*, 7022, 7014*, 7024:
7032:
±5%
±10%
±15%
±10%
±15%
* The first time delay afforded by Model 7012 with H (3 to 30 min.) and I (6 to 60
min.) time ranges or Model 7014 with H time range will be approx. 15% longer than
subsequent delays due to coil temperature rise.
Reset Time — 50 msec. (except model 7032)
Relay Release Time — 50 msec. for on-delay models (7012/7014)
Relay Operate Time — 50 msec. for off-delay models (7022/7024)
Operating Voltage Coil Data (for DPDT)
Coil
Part #
7000
AC
7010
DC
Code
Letter
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
Y
Z
X
Rated
Voltage
120
240
480
550
24
12
6
208
28
48
24
125
12
60
250
550
16
32
96
6
220
Operating*
Voltage
Range
@ 60Hz
102-132
204-264
408-528
468-605
20.5-26.5
10.2-13.2
5.1-6.6
178-229
Dual Voltage Coil
(Combines A&B)
Special AC Coils
(L1, L2, etc.)
22.4-30.8
38.4-52.8
19.2-26.4
100-137.5
9.6-13.2
48-66
200-275
440-605
12.8-17.6
25.8-35.2
76.8-105.6
4.8-6.6
176-242
Special DC Coils
(X1, X2, etc.)
Rated
Voltage
110
220
127
240
Operating
Voltage
Range
@50Hz
93.5-121
187-242
108-140
204-264
*Four pole Models: Operational voltage range 90% to 110% for AC units; 85% to
110% for DC units.
See next page for more coil data.
12–10
Catalog 5-1773450-5
Revised 3-13
www.te.com
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Dimensions are in millimeters USA: +1 800 522 6752
unless otherwise specified. Asia Pacific: +86 0 400 820 6015
UK: +44 800 267 666
For additional support numbers