408-10455 Datasheet, PDF (4/5 Pages) TE Connectivity Ltd – Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools
408-10455
3. If the crimp cannot be made to conform to the
recommended crimp height, the tool or die set must
be replaced. See Section 9, REPLACEMENT.
8. MAINTENANCE AND INSPECTION
8.1. Daily Maintenance
1. Remove dust, moisture, and other contaminants
with a clean, soft brush, or a clean, soft, lint-free
cloth. DO NOT use any objects that could damage
the dies or tool.
2. Make sure that the proper die retaining screws
are properly secured.
3. When the tool is not in use, keep the handles
closed to prevent objects from becoming lodged in
the dies. Store the tool in a clean, dry area.
4. Remove all lubrication and accumulated film from
the dies by immersing the dies in a suitable
commercial degreaser.
8.2. Inspection
Close the tool handles until the ratchet releases, and
then allow them to quickly open freely. If they do not
open quickly and fully, the spring is defective. See
Section 9, REPLACEMENT.
Inspect the crimping surfaces of the dies for flattened,
chipped, worn, or cracked areas. If damage is evident,
the dies must be replaced. Refer to Section 9,
REPLACEMENT.
9. REPLACEMENT
Order replacements through your representative, or
call 1-800-526-5142, or send a facsimile of your
purchase order to 717-986-7605, or write to:
CUSTOMER SERVICE (038-035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105-3608
10. REVISION SUMMARY
• Initial release of document
Rev A