408-32222
Pusher
Subassembly
Figure 4
Clamp
Subassembly
NOTE
The tool and receptacle can spin after removal due to the twisting action of the removal knob. This spin could cause damage
to the pc board. Hold the tool firmly during removal.
6. Remove the receptacle from the tool by loosening the Clamp Knob.
4. MAINTENANCE AND INSPECTION
TE Connectivity recommends that the tool be inspected immediately upon its arrival to ensure that it has not
been damaged during shipment.
4.1. Daily Maintenance
It is recommended that each operator be made aware of, and responsible for, the following steps of daily
maintenance:
 Remove dust, moisture, and other contaminants with a clean, soft brush, or lint-free cloth. DO NOT use
objects that could damage the tool or any of its components.
 When the tool is not in use, store it in a clean, dry area.
4.2. Periodic Inspection
Regular inspections should be performed by quality control personnel. A record of scheduled inspections
should remain with the tool or be supplied to personnel responsible for the tool. The inspection frequency
should be based on the amount of use, working conditions, operator training and skill, and established
company standards.
5. REPLACEMENT AND REPAIR
For customer repair service or to order replacement parts, call 1-800-522-6752, or fax your purchase order to
717-986-7605, or write to: Customer Service (038-035), Tyco Electronics Corporation, PO Box 3608,
Harrisburg, PA 17105-3608.
6. REVISION SUMMARY
 Initial release of document
Rev A
3 of 3