Vertical Pusher
Plate Orientation
408-32222
Horizontal Pusher
Plate Orientation
Figure 2
a. If a receptacle is located next to the clamp assembly, the pusher plate must have a horizontal
orientation.
b. If a printed circuit (pc) board is located next to the clamp assembly, the pusher plate must have a
vertical orientation.
c. If a guide module is located next to the clamp assembly, the guide module pusher plate must be
installed.
3.2. Removal Procedure
CAUTION
Be certain the removal tool assembly does not contact any components on the pc board during use.
1. Loosen the clamp knob on the clamp subassembly if necessary to fit over the receptacle.
2. Place the clamp subassembly over the receptacle and center it on the receptacle.
3. Tighten the clamp knob to clamp the receptacle. Hand tightening should be sufficient. See Figure 3.
Front Clamp Plate
Rear Clamp Plate
Clamp Knob
Figure 3
4. Place the pusher subassembly over the clamp subassembly. (Figure 4).
5. Tighten the Removal Knob to remove the receptacle from the pc board.
Rev A