English
Language : 

408-9875 Datasheet, PDF (2/4 Pages) TE Connectivity Ltd – Base Assembly Universal
408- 9875
ribbon cable in position. The cable stop provides
proper positioning of the ribbon cable for flush
terminations.
NOTE
i
The slot on the upper tool mount must face
toward the FRONT of the frame assembly, as
shown in Figure 1.
3. INSTALLATION OF BASE ASSEMBLY UNIVERSAL
ARBOR TOOL (Figure 1)
NOTE
i
The procedures in this section are typical for both
the Manual Arbor Frame Assembly and the
Pneumatic Auto- Cycle Unit.
2. Remove tool stop from the front of the slide
base.
3. Position lower tooling assembly onto slide base
of frame assembly and slide into position.
4. Replace tool stop and tighten it to secure the
lower tooling assembly onto the slide base.
DANGER
Before installing the universal arbor tool in the
Pneumatic Auto- Cycle Unit, DISCONNECT air
from main air valve.
1. Secure upper tool mount to ram with the two
socket head cap screws.
4. TERMINATION PROCEDURE
1. Install the connector--specific kit onto the
universal arbor tool; then set up the tooling
components for termination. Refer to the
instruction sheet supplied with the
connector--specific kit. See Figure 2.
MANUAL ARBOR
FRAME ASSEMBLY
(Ref)
TOOL HANDLE
RAM
REAR TOOL
STOP
CABLE
GUIDES
NOTE: GUARD REMOVED FOR CLARITY
2 of 4
UPPER TOOL
MOUNT
(Ref)
UPPER
TOOL
AMPLIMITE PLUG
CONNECTOR
CABLE POSITIONED IN FLUTES
OF FLUTED PLATE AND
BETWEEN CABLE GUIDES
Figure 2
CABLE CLAMP
CLOSED
LOCATORS
CABLE
STOP
(Ref)
LOWER
INSERT
Rev A