4. Holding the handle, turn the tool clockwise to
thread the plug connector together.
5. Continue turning the handle (and connector) until
the drive handle makes a "clicking" sound. This
clicking sound is an indication that the proper torque
has been reached.
6. Move the locking handle to the open position to
release the connector.
3.2. Removal
1. Place the hermetic plug connector into the collet.
NOTE
i
The connector should bottom on a stop within the
collet.
2. Once the connector is in place in the collet, move
the locking handle to the closed position. This
secures the connector in the tool.
CAUTION
Do not force the locking handle closed. If the
handle does not easily close the collet tension may
!
have to be adjusted.
3. If necessary, turn the adjustment nut until the
connector is held snuggly in place.
NOTE
i
The collet adjusting nut is covered with a heat
shrink tubing to help maintain adjustment.
4. Holding the handle, turn the tool
counterclockwise to unthread the plug connector.
5. Move the locking handle to the open position to
release the connector.
4. REPLACEMENT
The torque driver contains a 6.35 [.250] square drive
which accepts the replacement head (shown in 
Figure 1).
1. Pull the head off the standard 6.35 [.250] square
drive.
2. Snap the replacement head (Figure 1) onto the
square drive.
3. Order replacements from your TE representative,
or call 1-800-526-5142, or send a facsimile of your
purchase order to 1-717-986-7605, or write to:
CUSTOMER SERVICE (038-035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105-3608
For tool repair service, please contact a representative
at 1-800-526-5136.
5. REVISION SUMMARY
Since the previous release, the new company logo
was applied.
CAUTION
Damage to the connector may result if the collet is
not properly adjusted.
!
Rev A
2 of 2