408-8734 Datasheet, PDF (2/6 Pages) TE Connectivity Ltd – Terminating Modules
408-8734
Reasons for re-issue of this instruction sheet are provided in Section 8, REVISION SUMMARY.
When reading this document, pay particular attention to DANGER and CAUTION statements.
DANGER
Denotes an imminent hazard which may result in moderate or severe injury.
CAUTION
Denotes a condition which may result in product or equipment damage.
1. DESCRIPTION
These terminating modules fit interchangeably into the modular plug dual terminator. Each module features
dual nest areas for positioning the modular plugs, inserters for terminating the contacts, and stuffers for
terminating the primary and secondary strain reliefs. Since each feature is independently adjustable, crimp
heights can be adjusted to meet International Electrotechnical Commission (IEC) specifications.
2. INSTALLATION
1. Install the modular plug dual terminator according to 409-10010.
2. Disconnect the air supply.
DANGER
To avoid personal injury, always disconnect the air supply before attempting to install or remove the module from the
terminator. A lockout valve has been provided in the air line.
3. Remove the plastic guard from the module by removing four screws and two terminals from the limit
switch (refer to the module customer drawing for location).
4. For terminators -1 and -2 (only), refer to Figure 2, and:
a. Connect the cable from the automatic circuit tester to the back of the module, and tighten the
screws to secure cable.
b. Check that the two single-wire terminations on the limit switch to the left of the tester cable (viewing
from the back of the module) are firmly connected to the limit switch at the top-most and bottom-
most terminals (normally-closed position). Verify that the green wire of the tester cable is
connected to the terminator and to a suitable ground on an AC outlet.
c. Set up the automatic circuit tester according to 409-10010.
5. Position the module so that the T-slot at the top will slide onto the arm of the terminator so that the
module rests on the base plate of the terminator. Tighten the screws at the bottom front of the module,
securing the module to the base plate.
Using Terminators -1 and -2 Only
Tester Cable Connected to
Back of Module
Back of Terminator
Connect Green Wire of Tester Cable
to Suitable Ground on AC Outlet
Rev E
Figure 2
2 of 6