English
Language : 

408-8579 Datasheet, PDF (2/5 Pages) TE Connectivity Ltd – Securely tighten both screws with the appropriate screwdriver.
Crimping the Center Contact
Typical Plug
Contact
408-8579
Flange on End of
Contact
Stripped
Cable
Typical Jack
Contact
Crimping Die
Flange on End of
Contact
Anvil Die
Crimping Die
NOTE: Typical Crimping Dies Shown
Figure 2
3. Holding the cable in place, close the tool handles
until the ratchet releases.
4. Allow the tool handles to open fully and remove
the crimped center contact from the dies.
4.2. Crimping the Ferrule (Figure 3)
1. Insert the crimped center contact into the
connector body until the cable dielectric butts
against the dielectric inside the connector body or
until the center contact is securely positioned within
the connector. Make sure that the braided shield is
over the support sleeve of the connector body and
that no strands from the shield enter the connector
body.
2. Slide the ferrule up over the braided shield and
onto the connector until the ferrule butts against the
shoulder on the connector body.
3. Place the ferrule in the appropriate crimping
chamber of the anvil die so that the shoulder on the
connector body butts against the edge of the die.
NOTE
i
Refer to the instruction sheet packaged with the
connector to determine the appropriate crimping
chamber for the ferrule.
4. With a screwdriver, adjust the ratchet wheel from
the opposite side of the tool.
CAUTION
Make sure that both sides of the ferrule are started
evenly into the crimping chamber. Do not attempt to
!
crimp an improperly positioned ferrule.
5. Carefully close the tool handles until the ratchet
releases.
Crimping the Ferrule
Shoulder on
Connector Body
Butts Against
Edge of Die
Ferrule in Crimping
Chamber on Anvil
Die
NOTE: Typical Crimping Dies Shown
Figure 3
Rev C