English
Language : 

408-8340 Datasheet, PDF (2/3 Pages) TE Connectivity Ltd – Reasons for reissue of this instruction sheet are provided in Section 8, REVISION SUMMARY.
408-8340
3. INSTALLATION
DANGER
STOP
It is necessary to open or remove machine covers
to perform the following procedure. Be sure to
replace ALL covers BEFORE operating the
machine.
The cable clamp's pivot bracket attaches to the
machine carriage, and the cam track assembly
mounts to the machine's base block assembly. To
mount the clamp:
1. Turn off the machine's air supply by disengaging
the air supply at the back of the machine.
2. Turn off the machine's electrical functions by
switching the rocker switch on the back of the
machine's control module.
DANGER
STOP
DO NOT make adjustments to the machine or the
cable clamp while the machine is operational. Make
sure to disable the machine to prevent it from
moving while adjustments are being made.
3. Attach the pivot bracket to the back of the
machine carriage with the No. 10-32 screws
provided. Refer to Figure 2. Using a 5/32-in. hex
wrench, tighten the screws.
Pivot
Bracket
Screws and
Washers
Dimension “A”
(See Table)
Mounting
Screw
Base Block
Assembly (Ref)
CONNECTOR
TYPE
SIZE
20
40
50
AMPLIMITE .050
68
80
100
120
AMPLIMITE HDE
All
CHAMP
All
DIMENSION “A”
STRAIGHT
EXIT
ANGLE
EXIT
2.54 [.100]
1.27 [.050]
5.58 [.220] 13.97 [.550]
8.38 [.330] 15.24 [.600]
13.20 [.520] 26.67 [1.050]
17.01 [.670] 34.29 [1.350]
23.62 [.930] 46.99 [1.850]
33.52 [1.320] 55.88 [2.200]
18.54 [.730]
---
Figure 3
Carriage
Figure 2
4. Slide the bottom of the cam track assembly onto
the rack portion of the base block assembly. Make
sure that the cam track assembly mounting screw is
raised to allow the cam track to slide.
5. Adjust the position of the cam track assembly to
Dimension A shown in Figure 3 to ensure that the
cable is located for either straight exit or angle exit.
6. Using a 5/32-in. hex wrench, tighten the mounting
screw to secure the cam track.
7. On the machine, plug the air hose from the clamp
solenoid valve (see Figure 4) onto the fitting of the
cable clamp (refer to Figure 1).
8. Turn on the air to the machine, and inspect the
cable clamp for air leaks.
4. TOOLING ADJUSTMENTS
DANGER To avoid personal injury, DISCONNECT air and
electric power before making adjustments to the
STOP machine or cable clamp. DO NOT make
adjustments while the machine is operational.
4.1. Cable Clamp Position
The position of the cable clamp can be adjusted to
vary the cable exit position relative to the connector.
To adjust this position, refer to Figure 3, and proceed
as follows:
Rev B