English
Language : 

408-32145 Datasheet, PDF (2/5 Pages) TE Connectivity Ltd – Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools.
408-32145
3. INSTALLATION AND REMOVAL OF THE DIE ASSEMBLY (Figure 2)
1. Open the tool handles and remove the two die retaining screws from the tool jaws.
2. Slide the die assembly into the partially opened tool jaws.
3. Insert the die retaining screws and tighten the screws just enough to hold the dies in place. Do not
tighten the screws completely at this time.
4. Carefully close the tool handles, making sure the dies align properly. Continue closing the tool handles
until the ratchet in the tool frame has engaged sufficiently to hold the die in place, then tighten both die
retaining screws.
5. To disassemble, close the tool handles until the ratchet releases, remove the two die retaining screws,
and slide the dies out of the tool jaws.
Anvil Die
Tool Frame
Nest Die
Die Retaining
Screws
Figure 2
4. CRIMPING PROCEDURE
NOTE
Before using the tool, the crimping chamber and tool ratchet should be inspected as specified in Paragraph 5.2, Measuring Die
Opening, and Paragraph 5.3, Ratchet Adjustment.
Strip cable according to the proper dimensions and assemble the connector to the cable according to the
instructions in the appropriate connector instruction sheet. Then proceed as follows:
1. Place connector in the nest die so that the edge of the connector is flush with the edge of the die. See
Figure 3.
2. Holding the assembly in place, close the tool handles until the ratchet releases.
3. Remove the crimped assembly from the crimping die.
Connector in
Nest Die
Ferrule Flush with Edge of
Die Set (Or See Specific
Connector Instruction Sheet
for Placement)
Rev A
Figure 3
2 of 5