English
Language : 

CHS-UGS Datasheet, PDF (6/7 Pages) TDK Electronics – Humidity Sensor Units
(5/6)
CHS-C TYPE
For consumer and office equipment
FEATURES
• Temperature detection thermistor can be added.
• Humidity sensing characteristics exhibit virtually no hysteresis.
• Low current consumption.
• Absolute humidity can be read directly with DC. 1V voltmeter.
• All-in-one construction incorporates circuits and 5V power
supply operation.
• Generated ripple at low humidity levels will not exceed 2.5mV.
Type
Nominal accuracy(%)RH
Measuring range(%)RH
CHS-CMC-_ _
±5
30, 50, 80
MAXIMUM RATINGS (Ta=25°C)
Power supply voltage Edc
Operating conditions
Storage conditions
7V max.
0 to +50°C, power supply voltage 5V, without
dewing
–20 to +60°C, without dewing
SHAPES AND DIMENSIONS
34
7.0
20
Connector
4
Pin No. 1 +5V
3
Pin No. 2 Humidity output
2
1
(RHV)
Pin No. 3 GND•TH1
Pin No. 4 TH2
(5)
2-ø4.1±0.1
Humidity sensor
Components mounting region
Dimensions in mm
Tolerance: ±0.5
ELECTRICAL CHARACTERISTICS
Item
Operating voltage Edc (V)
Operating current(mA)
Output impedance(kΩ )
30(%)RH
Accuracy(%)RH
50(%)RH
80(%)RH
Hysteresis(%)RH
Temperature dependency(%)RH
Specifications
Minimum
Standard
4.75
5
–5
(0.5V)
–5
(0.86V)
–5
(1.5V)
–5
(200)
(0.6V)
(0.96V)
(1.6V)
≈0
Response time(min)
Recommended operating
temperature(°C)
1
+15
RECOMMENDED CHARACTERISTICS OF TEMPERATURE
DETECTION THERMISTOR
Part No.
Resistance value(Between TH1 and TH2)
Constant B
NTCCM16084BH103JC
10kΩ ±5%
4100K±3%
Maximum rated power
230mW
Maximum
5.25
0.6
+5
(0.7V)
+5
(1.06V)
+5
(1.7V)
+5
+35
Conditions
Edc=5V, 25°C
at DC
Edc=5V, 25°C
(For details, please refer to typical characteristics)
Stable time: 20 min
Edc=5V, 25°C standard
(For details, please refer to typical characteristics)
Response time to reach 90% of actual humidity as for from
30 to 85(%)RH
Edc=5V
• All specifications are subject to change without notice.
002-01 / 20100120 / eb111_chs.fm