English
Language : 

CHS-UGS Datasheet, PDF (4/7 Pages) TDK Electronics – Humidity Sensor Units
(3/6)
CHS-SS TYPE
For consumer and office equipment
FEATURES
• Humidity sensing characteristics exhibit virtually no hysteresis.
• Compact size.
• Low current consumption.
• Outputs DC.1V at 100(%)RH; relative humidity can be read
directly with a voltmeter.
• All-in-one construction integrates sensor with support circuitry.
The entire module operates off a 5V power supply.
• Generated ripple at low humidity levels will not exceed 2.5mV.
Type
Nominal accuracy(%)RH
Measuring range(%)RH
CHS-MSS
±5
20 to 85
SHAPES AND DIMENSIONS
SQUARE TYPE
10max.
Sensible
side∗1
CHS SS
R
Vout G+5
Label
5max.
Sensible
side∗1
MAXIMUM RATINGS (Ta=25°C)
Power supply
voltage Edc
Operating
conditions
Storage
conditions
7V max.
0 to +50°C, power supply voltage 5V, without dewing
–20 to +60°C, without dewing
0.5
0.25
123
Pin No. 1 Analog output voltage
Pin No. 2 GND
∗2
Pin No. 3 +Power supply voltage
∗1When installing the device, ensure that the humidity
sensing surface is not obstructed.
2.5
2.5 ∗2 The three leads are parallel to within 0.2mm.
Weight: 1.1g typ.
Dimensions in mm
Tolerance: ±0.2
ELECTRICAL CHARACTERISTICS
Item
Operating voltage Edc (V)
Operating current(mA)
Output voltage(mV)/(%)RH
Output impedance(kΩ )
Specifications
Minimum Standard
4.75
5
10
(200)∗
Accuracy(%)RH
–5
Hysteresis(%)RH
≈0
Temperature dependency(%)RH –5
Response time(min)
1
Recommended operating
temperature(°C)
+15
∗( ): Reference value
Maximum
5.25
0.6
+5
+5
+35
Conditions
Edc=5V, 25°C
Edc=5V, 25°C
at DC
Edc=5V, 25°C, 20 to 85(%)RH(For details, please refer to typical
characteristics)
Stable time: 20min
Edc=5V, 25°C standard
Response time to reach 90% of actual humidity as for from 30 to 85(%)RH
Edc=5V, without dewing(For details, please refer to typical characteristics)
• All specifications are subject to change without notice.
002-01 / 20100120 / eb111_chs.fm