English
Language : 

PMK130 Datasheet, PDF (2/10 Pages) Astrodyne Corporation – 130W Open Frame and U-Channel Power Supplies with PFC
130W Open Frame and U-Channel Power Supplies with PFC
PMK130 series
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input Voltage Range
Input Frequency Range
Inrush Current, typ:
Input Current
Power Factor (cold start)
Leakage Current
90-264VAC (100-240VAC Nom.)
47-63 Hz
Cold Start, 60A @ 230VAC Input *
2.3~0.8A (90-264VAC)
PF > 0.96 @ 230VAC
<3.5mA @ 264VAC, 50Hz
OUTPUT SPECIFICATIONS
Voltage and Current
Maximum Output Power
Preset Accuracy (Note 6)
Line Regulation (Note 5)
Load Regulation (20% to FL)
Ripple/Noise (Notes 1,2,7)
Turn On
Hold Up Time
Rise Time
Short Circuit Protection
Over Voltage Protection
Over Current Protection
Transient Response
Over Shoot/Under Shoot
See Selection Chart
130 Watts
1%
0.5% nom / 1% max
0.5% nom / 1% max
See Selection Chart
<4S, typ.
20mS, typ.
30mS, typ.
Auto recovery *
130% max., Auto recovery *
150% max., Auto recovery *
10mS
<10% of Nominal O/P VDC
GENERAL SPECIFICATIONS
Oper. Temperature (Note 4)
Storage Temperature
Relative Humidity
EMS Harmonics:
Fluctuations:
ESD:
RS:
EFT:
Surge:
CS:
Dips:
MTBF
Vibration
Drop Test
-10°C to +70°C (See Derate Curve)
-25°C to +85°C
10 to +90%, non-cond *
IEC61000-3-2 Class A
IEC61000-3-3
IEC61000-4-2, 6KV Contact, 8KV Air
IEC61000-4-3 FR: 80MHz-2.5GHz
Field Strength: 3V/M
IEC61000-4-4 2KV on AC Line
IEC61000-4-5 1KV (L-L);
2KV (L, N-PE)
IEC61000-4-6 3V (EMF)
IEC61000-4-11 95% 250CY,
70% 25CY, 40% 5CY, 5% 0.5CY
197,000 Hrs min. MIL-HDBK-217F
4G Pk, 50~500Hz, 3 Axes, 30 min*
Test Height 70cm *
PHYSICAL SPECIFICATIONS
Size Open Frame:
U-Channel:
Weight Open Frame:
U-Channel:
76.2 x 127 x 35.5mm (3” x 5” x 1.4”)
127 x 80.4 x 38mm
(5” x 3.17” x 1.50”)
10.25 oz (291g)
13.38 oz (380g)
Safety UL/cUL:
UL-EU:
CE:
CB:
Isolation (Note 3)
Insulation Resistance
EMI
Efficiency
UL60950-1 2nd ed./
C22.2 60950-1 2nd ed.
EN60950-1 2nd ed.
EN60601-1-2
IEC60950-1 2nd ed.
4242VDC I/P - O/P *
2828 VDC I/P - GND *
707VDC O/P - GND *
≥ 20MΩ (500VDC, 1S I/P-O/P)
CISPR EN55011 class B
See Selection Chart
WWW.ASTRODYNETDI.COM
NOTES:
1. All measurements should be made directly at the terminals of the
power supply.
2. Ripple and Noise depend upon output voltage a specified per
particular model.
3. Isolation for up to 1min duration.
4. Specified for free-air convection cooling.
5. Line regulation measured from 90 - 264VAC/100VAC minimum
required for full load start.
6. Preset accuracy measured at nominal load, 120VAC input.
7. O/P noise measured directly at pins/terminals @ nominal load, 0uF by
pass and 47uF electrolytic, pk-pk@ 20MHz bandwidth.
Special EMC Notice: The end application shall provide an earth ground
connection for conducted & radiated emission performance. Astrodyne is
not liable for the end application without extra earth connection to
PMMK130S Open Frame Power Supply.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458