English
Language : 

CC3-4805SR-E Datasheet, PDF (17/25 Pages) TDK Electronics – Insulation type DC-DC converter
CC15-E
17
CC15-E Specifications
ITEMS/UNITS
Nominal Voltage
MODEL
V
CC15-2403Sx-E
DC24
CC15-2405Sx-E
Input
Voltage Range
Efficiency (typ)
V
(*1) %
DC18-36
89
Current (typ)
(*1) A
0.695
0.702
Nominal Voltage
VDC
3.3
5
Maximum Current
A
4.500
3.000
Maximum Power
(*2) W
14.85
15
Maximum Line Regulation(Within input voltage range) mV
65
100
Maximum Load Regulation (0-100% load) mV
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
120
200
80mV
Max Power Total Regulation (max)(*3) %
+5/-3
Maximum Ripple & Noise (typ/max) (*4) mVp-p
40/120
Voltage Adjustable Range
Not available
Over Current Protection
(*5)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
Operating Temperature
℃
-40 to +85
Storage Temperature
℃
-40 to +85
Environment
Operating Humidity
Storage Humidity
% RH
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Isolation Resistance
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ)
Size (W x H x D)
g
mm
12.5
DIP: 37.55 x 7.0 x 32.1 / SMD: 37.55 x 7.5 x 32.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) Output voltage includes input change, load change (balanced load), and temperature change.
(*4) In 50MHz, Ta=25°C.
(*5) Latch method Resumes by restarting input or resetting remote on/off.
・All specifications are subject to change without notice.