CC10-E
14
CC10-E Specifications
ITEMS/UNITS
Nominal Voltage
MODEL CC10-0503Sx-E CC10-0505Sx-E
V
CC10-0512Sx-E
DC5.0
CC10-0512Dx-E
Input
Voltage Range
Efficiency (typ)
V
(*1) %
DC4.5-9.0
84
83
Current (typ)
(*1) A
1.964
2.381
2.286
2.313
Nominal Voltage
VDC
3.3
5
12
15
± 12
± 15
Maximum Current
A
2.500
2.000
0.800
0.640
0.400
0.320
Maximum Power
(*2) W
8.25
10
9.6
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
40
80mV
100
200mV
600
300mV
Max Power Total Regulation (max)(*4) %
±3
±5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
3.15-3.6
4.75-6.0
11.4-15.0
± 11.4- ± 15.0
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
Operating Temperature
℃
-40 to +85
Storage Temperature
℃
-40 to +85
Environment
Operating Humidity
Storage Humidity
% RH
% RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Isolation Resistance
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ)
Size (W x H x D)
g
mm
10
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
ITEMS/UNITS
Nominal Voltage
MODEL CC10-1203Sx-E CC10-1205Sx-E
V
CC10-1212Sx-E
DC12
CC10-1212Dx-E
Input
Voltage Range
Efficiency (typ)
V
(*1) %
84
86
DC9.0-18
88
86
Current (typ)
(*1) A
0.318
0.969
1.136
1.047
Nominal Voltage
VDC
3.3
5
12
15
± 12
± 15
Maximum Current
A
2.500
2.000
1000
800
450
360
Maximum Power
(*2) W
8.25
10
12
10.8
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
40
80mV
100
200mV
600
300mV
Max Power Total Regulation (max)(*4) %
±3
±5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
3.15-3.6
4.75-6.0
11.4-15.0
± 11.4- ± 15.0
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
Operating Temperature
℃
-40 to +85
Storage Temperature
℃
-40 to +85
Environment
Operating Humidity
Storage Humidity
% RH
% RH
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Isolation Resistance
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
Standards Safety Standards
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ)
Size (W x H x D)
g
mm
10
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.