English
Language : 

TCS3200 Datasheet, PDF (3/14 Pages) TEXAS ADVANCED OPTOELECTRONIC SOLUTIONS – COLOR LIGHT-TO-FREQUENCY CONVERTER
TCS3200, TCS3210
PROGRAMMABLE
COLOR LIGHT-TO-FREQUENCY CONVERTER
TAOS099A − AUGUST 2011
Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 V
Input voltage range, all inputs, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to VDD + 0.3 V
Operating free-air temperature range, TA (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
Storage temperature range (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
Solder conditions in accordance with JEDEC J−STD−020A, maximum temperature (see Note 3) . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to GND.
2. Long-term storage or operation above 70°C could cause package yellowing that will lower the sensitivity to wavelengths < 500nm.
3. The device may be hand soldered provided that heat is applied only to the solder pad and no contact is made between the tip of
the solder iron and the device lead. The maximum time heat should be applied to the device is 5 seconds.
Recommended Operating Conditions
Supply voltage, VDD
High-level input voltage, VIH
Low-level input voltage, VIL
Operating free-air temperature range, TA
VDD = 2.7 V to 5.5 V
VDD = 2.7 V to 5.5 V
MIN NOM MAX UNIT
2.7
5 5.5 V
2
VDD
V
0
0.8 V
−40
70 °C
Electrical Characteristics at TA = 25°C, VDD = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
VOH
High-level output voltage
VOL
Low-level output voltage
IIH
High-level input current
IIL
Low-level input current
IDD
Supply current
IOH = − 2 mA
4
IOL = 2 mA
Power-on mode
Power-down mode
S0 = H, S1 = H
500
Full-scale frequency (See Note 4)
S0 = H, S1 = L
100
S0 = L, S1 = H
10
Temperature coefficient of responsivity
λ ≤ 700 nm, −25°C ≤ TA ≤ 70°C
kSVS Supply voltage sensitivity
VDD = 5 V ±10%
NOTE 4: Full-scale frequency is the maximum operating frequency of the device without saturation.
TYP
4.5
0.25
1.4
600
120
12
± 200
±0.5
MAX UNIT
V
0.40 V
5 μA
5 μA
2 mA
0.1 μA
kHz
kHz
kHz
ppm/°C
%/ V
The LUMENOLOGY r Company
r
r
www.taosinc.com
Copyright E 2011, TAOS Inc.
3