15.High Temperature Loading
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
: No abnormality
: ±3% max
: 0.35% max
: 50MΩμF or 1000MΩ, whichever is smaller
Test Methods and
Remarks
According to JIS C 5102 clause 9.10.
Temperature
Duration
Applied voltage
Charge/discharge current
Measurement shall be conducted
: Maximum operating temperature
: 1000 +48/-0 hrs
: Rated voltage x 2
: 50mA max
: 24 ±2hrs under the standard condition
Note1
Note1 Standard condition: Temperature: 5 to 35℃, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa
When there are questions concerning measurement results, in order to provide correlation data, the test shall be conducted under the following
condition.
Temperature: 20±2℃, Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa
Unless otherwise specified, all the tests are conducted under the "standard condition".
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
c_mlcc_CFcap_reli_e-E02R01