English
Language : 

JMK105BJ474KV-F Datasheet, PDF (39/48 Pages) Taiyo Yuden (U.S.A.), Inc – Please read this notice before using the TAIYO YUDEN products.
10.Solderability
Specified Value
Test Methods and
Remarks
At least 95% of terminal electrode is covered by new solder.
Solder type
Solder temperature
Duration
Eutectic solder
H60A or H63A
230±5℃
4±1 sec.
Lead-free solder
Sn-3.0Ag-0.5Cu
245±3℃
11.Resistance to Soldering Heat
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
Withstanding voltage
: No abnormality
: ±2.5% max.
: Initial value
: Initial value
(between terminals) : No abnormality
Test Methods and
Remarks
Solder temp.
Duration
Preheating conditions
Measurement shall be conducted
: 270 ±5℃
: 3 ±0.5 sec.
: 80 to 100℃, 2 to 5 min. or 5 to 10 min.
150 to 200℃, 2 to 5 min. or 5 to 10 min.
: 24±2hrs under the standard condition Note1
12.Temperature Cycle (Thermal Shock)
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
Withstanding voltage
: No abnormality
: ±2.5% max
: Initial value
: Initial value
(between terminals): No abnormality
Test Methods and
Remarks
Conditions for 1 cycle
Step
temperature(℃)
Time(min.)
1
Minimum operating temperature
30±3 min.
2
Normal temperature
2 to 3 min.
3
Maximum operating temperature
30±3 min.
4
Normal temperature
2 to 3 min.
Number of cycles: 5 times
Measurement shall be conducted : 24±2hrs under the standard condition Note1
13.Humidity (Steady state)
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
: No abnormality
: ±5% max
: 0.5% max
: 50MΩμF or 1000MΩ, whichever is smaller
Test Methods and
Remarks
Temperature
Humidity
Duration
Measurement shall be conducted
: 40±2℃
: 90 to 95% RH
: 500 +24/-0 hrs
: 24 ±2hrs under the standard condition
Note1
14.Humidity Loading
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
: No abnormality
: ±7.5% max
: 0.5% max
: 25MΩμF or 500MΩ, whichever is smaller
Test Methods and
Remarks
According to JIS C 5102 clause 9.9.
Temperature
Humidity
Duration
Applied voltage
Charge/discharge current
Measurement shall be conducted
: 40±2℃
: 90 to 95% RH
: 500 +24/-0 hrs
: Rated voltage
: 50mA max
: 24 ±2hrs under the standard condition
Note1
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
c_mlcc_CFcap_reli_e-E02R01