10ï¼Solderability
Specified Value
Test Methods and
Remarks
At least 95% of terminal electrode is covered by new solder.
Solder type
Solder temperature
Duration
Eutectic solder
H60A or H63A
230±5â
4±1 sec.
Lead-free solder
Sn-3.0Ag-0.5Cu
245±3â
11ï¼Resistance to Soldering Heat
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
Withstanding voltage
: No abnormality
: ±2.5% max.
: Initial value
: Initial value
ï¼between terminalsï¼ : No abnormality
Test Methods and
Remarks
Solder temp.
Duration
Preheating conditions
Measurement shall be conducted
: 270 ±5â
: 3 ±0.5 sec.
: 80 to 100â, 2 to 5 min. or 5 to 10 min.
150 to 200â, 2 to 5 min. or 5 to 10 min.
: 24±2hrs under the standard condition Note1
12ï¼Temperature Cycle ï¼Thermal Shockï¼
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
Withstanding voltage
: No abnormality
: ±2.5% max
: Initial value
: Initial value
ï¼between terminalsï¼: No abnormality
Test Methods and
Remarks
Conditions for 1 cycle
Step
temperatureï¼âï¼
Timeï¼min.ï¼
1
Minimum operating temperature
30±3 min.
2
Normal temperature
2 to 3 min.
3
Maximum operating temperature
30±3 min.
4
Normal temperature
2 to 3 min.
Number of cycles: 5 times
Measurement shall be conducted : 24±2hrs under the standard condition Note1
13ï¼Humidity ï¼Steady stateï¼
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
: No abnormality
: ±5% max
: 0.5% max
: 50MΩμF or 1000MΩ, whichever is smaller
Test Methods and
Remarks
Temperature
Humidity
Duration
Measurement shall be conducted
: 40±2â
: 90 to 95% RH
: 500 ï¼24/ï¼0 hrs
: 24 ±2hrs under the standard condition
Note1
14ï¼Humidity Loading
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
: No abnormality
: ±7.5% max
: 0.5% max
: 25MΩμF or 500MΩ, whichever is smaller
Test Methods and
Remarks
According to JIS C 5102 clause 9.9.
Temperature
Humidity
Duration
Applied voltage
Charge/discharge current
Measurement shall be conducted
: 40±2â
: 90 to 95% RH
: 500 ï¼24/ï¼0 hrs
: Rated voltage
: 50mA max
: 24 ±2hrs under the standard condition
Note1