17. High Temperature Loading
Specified
Value
Temperature
Compensatingï¼Class1ï¼
Standard
Appearance
Capacitance change
Q
High Frequency Type
Insulation resistance
Appearance
Capacitance change
Insulation resistance
: No abnormality
: Within ±3% or ±0.3pF, whichever is larger.
: Cï¼10pFï¼ Qâ§200ï¼10C
10â¦Cï¼30pFï¼Qâ§275ï¼2.5C
Câ§30pFï¼ Qâ§350ï¼Cï¼Nominal capacitanceï¼
: 1000 MΩ min.
: No abnormality
: Within ±3% or ±0.3pF, whichever is larger.
: 1000 MΩ min.
High Permittivity ï¼Class2ï¼ Note 1
Appearance
: No abnormality
Capacitance change : Within ±12.5% ï¼BJ, B7, C6, C7, LD(â»)ï¼
Within ±30% ï¼Fï¼
Dissipation factor
: 5.0% max.ï¼BJ, B7, C6, C7, LD(â»)ï¼
11.0% max.ï¼Fï¼
Insulation resistance : 50 MΩμF or 1000 MΩ, whichever is smaller.
Note: â»LD Low distortion high value multilayer ceramic capacitor
Test
Methods and
Remarks
Preconditioning
Temperature
Duration
Applied voltage
Charge/discharge
current
Recovery
Class 1
Standard
High Frequency Type
None
Maximum operating temperature
1000ï¼48/ï¼0 hrs
Rated voltageÃ2
50mA max.
6 to 24hr ï¼Standard conditionï¼ Note 5
Class 2
BJ, LD(â»), F
C6
B7, C7
Voltage treatmentï¼Twice the rated voltage shall be applied for
1 hour at 85â, 105â or 125âï¼ Note 3, 4
Maximum operating temperature
1000ï¼48/ï¼0 hrs
Rated voltageÃ2 Note 4
50mA max.
24±2 hrs ï¼Standard conditionï¼ Note 5
Note: â»LD Low distortion high value multilayer ceramic capacitor
Note 1 The figures indicate typical specifications. Please refer to individual specifications in detail.
Note 2 Thermal treatment : Initial value shall be measured after test sample is heat-treated at 150ï¼0/ï¼10â for an hour and kept at room temperature for
24±2hours.
Note 3 Voltage treatment : Initial value shall be measured after test sample is voltage-treated for an hour at both the temperature and voltage specified in
the test conditions, and kept at room temperature for 24±2hours.
Note 4 150% of rated voltage is applicable to some items. Please refer to their specifications for further information.
Note 5 Standard condition: Temperature: 5 to 35â, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa When there are questions concerning
measurement results, in order to provide correlation data, the test shall be conducted under the following condition.
Temperature: 20±2â, Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa Unless otherwise specified, all the tests are conducted under the
"standard condition".
ⶠThis catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
c_mlcc_reli_e-E02R01
|
▷ |