PQ60150SMX03 Datasheet, PDF (8/15 Pages) SynQor Worldwide Headquarters – Output current limit and short circuit protection
Technical Specification
Input: 48V
Output: 15V
Current: 3A
5
4
3
2
400LFM(2.0m/s)
300LFM(1.5m/s)
1
200LFM(1.0m/s)
100LFM(0.5 m/S)
0
25
40
55
70
85
Ambient Air Temperature(°C)
Figure 7: Maximum output power derating curves vs. ambient air
temperature for airflow rates of 100 LFM through 400 LFM with air
flowing lenghtwise from input to output (nominal input voltage).
Figure 8: Thermal plot of converter at 3.0 amp load current (45W)
with 55°C air flowing at the rate of 200 LFM. Air is flowing across the
converter from input to output (nominal input voltage).
Figure 9: Turn-on transient at full load (resistive load) (10 ms/div). Input
voltage pre-applied. Top Trace: Vout (10V/div). Bottom Trace: ON/OFF
input(5V/div)
Figure 10: Turn-on transient at zero load (10 ms/div). Top Trace: Vout
(10V/div). Bottom Trace: ON/OFF input (5V/div)
Figure 11: Output voltage response to step-change in load current (50%-75%-50%
of Iout(max); dI/dt = 0.1A/µs). Load cap: 100µF electrolytic output capacitance.
Top trace: Vout (200mV/div). Bottom trace: Iout (1A/div).
Figure 12: Output voltage response to step-change in load current (50%-
75%-50% of Iout(max): dI/dt = 2A/µs). Load cap: 330µF electrolytic output
capacitance. Top trace: Vout (200mV/div). Bottom trace: Iout (1A/div).
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11