English
Language : 

PQ60050HGA30 Datasheet, PDF (8/14 Pages) SynQor Worldwide Headquarters – 30 Amp, No Heatsink, Isolated DC/DC Converter
Performance Curves
Half
Brick
48Vin 5.0Vout 30A
1
0.1
0.01
0.001
36 Vin
48 Vin
75 Vin
0.0001
10
100
1,000
10,000
100,000
Hz
Figure 19: Magnitude of incremental output impedance (Zout =
vout/iout) for minimum, nominal, and maximum input voltage at full
rated power.
0
-10
-20
36 Vin
-30
48 Vin
75 Vin
-40
-50
-60
10
100
1,000
10,000
100,000
Hz
Figure 21: Magnitude of incremental reverse transmission (RT =
iin/iout) for minimum, nominal, and maximum input voltage at full rated
power.
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
-110
10
36 Vin
48 Vin
75 Vin
100
1,000
10,000
100,000
Hz
Figure 20: Magntiude of incremental forward transmission (FT =
vout/vin) for minimum, nominal, and maximum input voltage at full
rated power.
100
10
36 Vin
48 Vin
75 Vin
1
0.1
10
100
1,000
10,000
100,000
Hz
Figure 22: Magnitude of incremental input impedance (Zin = vin/iin)
for minimum, nominal, and maximum input voltage at full rated power.
Product # PQ60050HGA30
Phone 1-888-567-9596
Doc.# 005-2HG650C Rev. E
9/30/08
Page 8