AQ1400IUXX Datasheet, PDF (7/8 Pages) SynQor Worldwide Headquarters – Integral fan cooling with speed control
AC Input: 85-264Vrms
DC Output: 12/15/24/28/48V
Power: 1400W
Grade: Industrial
INSTALLATION INSTRUCTIONS
GENERAL INFORMATION: ACuQor AC/DC power
supplies are intended for use as components in medical
and industrial equipment. ACuQor units must be
properly installed within end use equipment before they
can be safely applied as described in this document.
The suitability of the ACuQor/equipment combination
must be verified through end product investigation.
MOUNTING: Refer to the Mechanical Drawings section.
ACuQor units are provided with threaded stainless-
steel stand-offs or inserts for mounting. This mounting
hardware is internally connected to the input connector
protective-earth terminal for functional-earth EMC control.
Any orientation (vertical, horizontal, etc.) may be used.
Adequate air space should be provided over the fan
intake (top) and exhaust (sides) to allow for exchange of
cooling air. ACuQor is designed for a pollution degree 2
environment. A minimum of 5 mm electrical clearance should
be allowed from the connector ends of encased models.
INPUT: Refer to the Connector Details section for input
connector wiring. ACuQor products require a single phase
AC power source of 100-240V 50/60Hz nominal. Refer to
nameplate label for input current ratings. A protective-
earth connection is also required. Minimum wire size of 14
AWG (2.5mm2) is recommended. Both sides of the AC line
are internally fused (see table for specific models). These
fuses are not user replaceable.
OUTPUT: Refer to the Connector Details section for the
output connector wiring and signal I/O functionality.
Refer to nameplate label for output current ratings.
Main DC output (Vout+, Vout-) pins should use 12 AWG
(4.0mm2) wire size. Individual main output pins should
not be loaded to more than 30 A. For currents greater
than 30 A, multiple main output pins/wires must be used
in parallel. All signal I/O pins are referenced to Vout-.
EMC: ACuQor products have been tested to the EMC
specifications listed in the section of the datasheet titled
Electrical Characteristics, on page two. However, end
use equipment must be tested to verify EMC compliance.
HIPOT TESTING: ACuQor products are rated for Hipot
testing levels of 1500 Vac input to protective-earth, 500
Vac output to protective-earth, and 3000 Vac input to
output. When performing the 3000 Vac input to output
test, the test voltage must be balanced evenly 1500 Vac
input and output to protective-earth. Two oppositely
phased test voltage sources or a single test voltage
source with external balancing impedances (capacitors)
may be used to prevent overstressing input or output
to protective-earth insulation per IEC/EN 60950-1.
CONDUCTIVE COOLING: This product requires
supplemental conductive cooling through its case to
maintain the rated output power. The case should be
mounted to a system chassis or heat sink with a thermally
conductive interface material and kept at 50°C maximum
to maintain full power rating of the product. For detailed
applications assistance, consult Applications Engineering
through the sales channel.
MODEL
AQ0800
AQ1100
AQ1400
Input Fuses
(in Both AC Lines)
Cooper Bussmann 20A 250V GBB-20
Cooper Bussmann 20A 250V GBB-20
Cooper Bussmann 20A 250V GBB-20
Fuses
Total
2
2
2
Table 2: AC line fuse for specific ACuQor Industrial Models
Product # AQ1400IUxx
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-0005979 Rev. E 10/01/15