English
Language : 

AQ1400IUXX Datasheet, PDF (2/8 Pages) SynQor Worldwide Headquarters – Integral fan cooling with speed control
AC Input: 85-264Vrms
DC Output: 12/15/24/28/48V
Power: 1400W
Grade: Industrial
ACuQor 1400W Series Electrical Characteristics
All specifications typical with TA = 25 °C, unless otherwise specified. Specifications subject to change without notice.
MAIN OUTPUT SPECIFICATIONS
Output power (continuous) 85-132/170-264 Vrms
(5 s transient)
85-132/170-264 Vrms
132-170 Vrms
Nominal DC output
12 Vout
voltage (at 800W)
15 Vout
(Semi-regulated)
24 Vout
28 Vout
48 Vout
Efficiency (see figs. 1 - 10) 12 Vout, 115 Vrms, 1400W
24 Vout, 115 Vrms, 1400W
48 Vout, 115 Vrms, 1400W
12 Vout, 230 Vrms, 1400W
24 Vout, 230 Vrms, 1400W
1400W
1800W
See Figure 12
12.4 V
15.6 V
25 V
29 V
50 V
87% typ.
89% typ.
90% typ.
89.5% typ.
90.5% typ.
Fundamental ripple freq.
Audible noise
Weight
MTBF
GENERAL SPECIFICATIONS
Input
Output
Fan speed varies with temp.
( AQ0800xxxxGC )
( AQ1100xxxxGC )
( AQ1400xxxxGC )
MIL-217
Demonstrated
Isolation voltage
ISOLATION SPECIFICATIONS
Input to output
Input to ground
Output to ground
500 kHz
250 kHz
45 dBA @ 1 m max.
998 g (35.2 oz)
1179 g (41.6 oz)
1179 g (41.6 oz)
533 kHours
TBD kHours
3000 Vrms
1500 Vrms
500 Vrms
48 Vout, 230 Vrms, 1400W
Hold-up time (to -20%) 12 / 15 Vout
24 / 28 / 48 Vout
Maximum load capacitance 12 Vout
15 Vout
24 Vout
28 Vout
48 Vout
91.5% typ.
10 ms @ 1400W
12 ms @ 1400W
48,000 µF
40,500 µF
24,000 µF
19,200 µF
6,000 µF
Insulation resistance
Leakage currents
Output to ground
ENVIRONMENTAL CHARACTERISTICS
Thermal performance
Operating ambient (see Fig 11)
Non-operating ambient
Relative humidity
Non-condensing
10 MΩ min.
See Note 2
-40 ºC to +70 ºC
-40 ºC to +85 ºC
5-95% RH
Output ripple voltage
Turn-on delay
Transient response
Overvoltage protection
Short circuit protection
Total regulation
Auxiliary Output
Thermal protection
REMOTE_ENABLE
AC input voltage
Input frequency
Input current
Power factor
Input surge current
Internal input fuses
Switching frequency (20 MHz BW)
Twice line frequency (at 800W)
0.5% p-p
5.0% p-p
2 s max.
Iout steps from 50-75%
At 0.2 A/µs
Cyclic restart
Cyclic operation
Over line, load and temperature
Always on (See Note 1)
Automatic recovery
Input Low Voltage
Input High Voltage
INPUT SPECIFICATIONS
Universal range
3% typ / 6% max. dev.
100 ms recovery
110-120%
115% rated Iout
±6.0%
5 V @ 100 mA
+125 ºC (PCB Temp)
0.45 V (max)
4.15 V (min)
85-264 Vrms
115 Vrms @ 1400W
230 Vrms @ 1400W
264 Vrms (cold start)
Both AC lines
47-63 Hz
14 Arms
7 Arms
>0.98
50 A max.
20 A
Altitude
Random vibration
Shock
Conducted emissions
Line frequency harmonics
Voltage fluctuations
ESD air
ESD contact
Radiated immunity
Fast transients
Line surge immunity
Conducted immunity
Power freq. mag. field
Voltage dip immunity
Operating
Non-operating
5-500 Hz
Half-sine, 10 ms, 3 axes
EMC CHARACTERISTICS
EN55011 and EN55022, FCC
part15
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
NOTES:
10,000 ft max.
30,000 ft max.
0.03 g2/Hz
20 g peak
Level B
Class A
Clause 5b
Level 3
Level 3
Level 3
Level 3
Level 3
Level 3
3 A/m
Perf Criteria B, A, B
<5% UT 10 ms,
70% UT 500 ms,
40% UT 100 ms
1. Derate 2 mA per °C above 50 °C ambient temperature.
2. Leakage currents see page 4.
SAFETY AGENCY CERTIFICATIONS
CAN/CSA-C22.2 No. 60950-1:2007
UL 60950-1:2007
EN 60950-1/A1:2010
CE Marked
Product # AQ1400IUxx
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-0005979 Rev. E 10/01/15
Page 2