English
Language : 

PQ60120EGL07 Datasheet, PDF (6/13 Pages) SynQor Worldwide Headquarters – Eighth-brick DC/DC Converter
Technical Specification
Input: 35-75 V
Output: 12 V
Current: 6.25 A
Package: Eighth-brick
7
6
5
4
400 LFM (2.0 m/s)
3
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
2
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 7: Maximum output power-derating curves vs. ambient air tem-
perature for airflow rates of 100 LFM through 400 LFM with air flow-
ing from input to output (nominal input voltage).
Figure 8: Thermal plot of converter at 6.25 amp load current (75W)
with 55°C air flowing at the rate of 200 LFM. Air is flowing across the
converter from input to output (nominal input voltage).
Figure 9: Turn-on transient at full load (resistive load) (5 ms/div).
Input voltage pre-applied. Ch 1: Vout (5V/div). Ch 2: ON/OFF input
(5V/div)
Figure 10: Turn-on transient at zero load (10 ms/div). Ch 1: Vout
(5V/div). Ch 2: ON/OFF input (5V/div).
Figure 11: Output voltage response to step-change in load current (50%-
75%-50% of Iout(max); dI/dt = 0.1A/µ s). Load cap: 10µ F, 100 mW ESR tanta-
lum cap and 1µ F ceramic cap. Ch 1: Vout (500mV/div), Ch 2: Iout (2.5A/div).
Figure 12: Output voltage response to step-change in load current (50%-
75%-50% of Iout(max): dI/dt = 1A/µ s). Load cap: 470µ F, 30 mW ESR tanta-
lum cap and 1µ F ceramic cap. Ch 1: Vout (200mV/div), Ch 2: Iout (2.5A/div).
Product # PQ60120EGL07
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2EG612D Rev. B
8/23/07
Page 6