English
Language : 

BQ4H480FTX64 Datasheet, PDF (6/14 Pages) –
Technical Specification
Input: 230-400 V
Output: 48 V
Current: 64 A
Package: Full-brick
Compliance & Testing
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
Pending
UL 60950-1
Basic insulation
EN 60950-1
CAN/CSA C22.2 No. 60950-1
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Parameter
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
# Units
32
5
5
10
5
5
5
15 pins
Test Conditions
Pending
95% rated Vin and load, units at derating point, 1000 hours
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x, y and z axis
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day
MIL-STD-883, method 2003
Product # BQ4H480FTx64
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0006678 Rev. 5
07/18/16
Page 6