English
Language : 

BQ4H480FTX64 Datasheet, PDF (5/14 Pages) –
Technical Specification
Input: 230-400 V
Output: 48 V
Current: 64 A
Package: Full-brick
BQ4H480FTx64 Electrical Characteristics (continued)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 385 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C base plate
temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
Min. Typ. Max. Units Notes & Conditions
DYNAMIC CHARACTERISTICS
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
350
mV 50% to 75% to 50% Iout max
Settling Time
150
µs To within 1% Vout nom
Turn-On Transient
Turn-On Time (with 3 mF output capacitance)
5
ms Half load (resistive), Vout=90% nom. Note 4
Start-Up Inhibit Time
200
ms -40 °C to +125 °C; Figure F
Output Voltage Overshoot
0
% 3 mF load capacitance
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
4250
V See Absolute Maximum Ratings
Isolation Resistance
100
MΩ
Isolation Capacitance (input to output)
N/A
pF Note 5
Semiconductor Junction Temperature
125
°C Package rated to 150 °C
Board Temperature
125
°C UL rated max operating temp 130 °C
Transformer Core Temperature
125
°C
Maximum Base-Plate Temperature, Tb
100
°C
FEATURE CHARACTERISTICS
Switching Frequency
150
175
200
kHz
Clock Synchronization
400
500
kHz
ON/OFF Control
Application notes Figures A & B
On-State Voltage
-1
0.4
V
Off-State Voltage
2
18
V
Pull-Up Voltage
5
V
Pull-Up Resistance
124
kΩ
Over-Temperature Shutdown OTP Trip Point
140
150
°C Average PCB Temperature
Over-Temperature Shutdown Restart Hysteresis
10
°C
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia) TR-NWT-000332
0.811
106 Hrs. 80% load, 200 LFM, 40 °C Ta
Calculated MTBF (MIL-217) MIL-HDBK-217F
0.717
106 Hrs. 80% load, 200 LFM, 40 °C Ta
Field Demonstrated MTBF
106 Hrs. See our website for details
Note 1: Converter will undergo input over-voltage
Note 2: UL’s product certification tests were carried out using 12.5 A fast blow fuse. Fuse interruption characteristics have to be taken into account while
designing input traces. User should ensure that Input trace is capable of withstanding fault currents.
Note 3: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 4: Starting up under full load can result in hic-up operation (shut down).
Note 5: Isolation capacitance can be added external to the module (recommended).
Product # BQ4H480FTx64
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0006678 Rev. 5
07/18/16
Page 5