English
Language : 

PQ60280FTA26 Datasheet, PDF (5/14 Pages) SynQor Worldwide Headquarters – Full-brick DC/DC Converter
Technical Specification
Input: 36-75 V
Output: 28 V
Current: 26 A
Package: Full-brick
ELECTRICAL CHARACTERISTICS (Continued)
Parameter P
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control (Option P)
On Current (threshold)
Off Current (threshold)
ON/OFF Control (Option N)
On Current (threshold)
Off Current (threshold)
Maximum allowable current through ON/OFF Pin
Auxiliary Power Supply Voltage
Auxiliary Power Supply Current
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
Load Current Scale Factor
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
Min.
275
0.1
0.1
6.0
0.0
-50
33
Typ.
300
0.5
0.5
35
120
10
833
2.13
1.93
TBD
Max.
325
1
50
50
1
4
9.0
20.0
+15
+15
37
Units Notes & Conditions
kHz Regulation and isolation stages
mA
µA
µA
mA
mA
V
mA
% Measured across Pins 9 & 5; Figure C
% Measured across Pins 9 & 5
V Over full temp range; % of nominal Vout
°C Average PCB Temperature
°C
See App Note: Output Load Current Calc.
106 Hrs. TR-NWT-000332; 80% load,300LFM, 40°C Ta
106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40°C Ta
106 Hrs. See our website for details
STANDARDS COMPLIANCE
Parameter P
STANDARDS COMPLIANCE
UL/cUL 60950-1
EN60950-1
72/23/EEC
93/68/EEC
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
Telcordia (Bellcore) GR-513
Notes
File # E194341, Basic insulation & pollution degree 2
Certified by TUV
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8kV - NP, 15kV air - NP (Normal Performance)
Section 7 - electrical safety, Section 9 - bonding/grounding
• An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety
certificates on new releases or download from the SynQor website.
QUALIFICATION TESTING
Parameter P
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
# Units Test Conditions
32
5
5
10
5
5
5
15 pins
95% rated Vin and load, units at derating point, 1000 hours
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off
MIL-STD-883, method 2003 and JESD22-B102D
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
robust, reliable product. Contact the factory for official product family qualification documents.
OPTIONS
SynQor provides various options for this family of dc-dc convert-
ers. Please consult the last page for additional information.
PATENTS
SynQor is protected under various patents. Please consult the
last page for further details.
Product # PQ60280FTA26
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2FT628P Rev. C
5/21/08
Page 5