English
Language : 

PQ60120QZB33 Datasheet, PDF (5/13 Pages) SynQor Worldwide Headquarters – Protection from permanent damage and hazardous conditions
Technical Specification
Input:35-75V
Output:12V
Current:33A
Part No.:PQ60120QZB33
Standards Compliance & Qualification Testing
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
UL 60950-1/R2011-12
Basic insulation
EN60950-1/A2:2013
CAN/CSA-C22.2 No. 60950-1/A1:2011
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Parameter
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
# Units Test Conditions
32
5
5
10
5
5
5
15 pins
95% rated Vin and load, units at derating point, 1000 hours
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x, y and z axis
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day
MIL-STD-883, method 2003
Product # PQ60120QZB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005586 Rev. G
02/04/15
Page 5