English
Language : 

PQ60120HZA50 Datasheet, PDF (5/13 Pages) SynQor Worldwide Headquarters – Half-brick DC/DC Converter
Technical Specification
Input: 35-75 V
Output: 12 V
Current: 50 A (600W)
Package: Half-brick
ELECTRICAL CHARACTERISTICS (Continued)
Parameter P
FEATURE CHARACTERISTICS
Switching Frequency Regulation Stage
Switching Frequency Isolation Stage
ON/OFF Control (Option P)
Off-State Voltage
On-State Voltage
ON/OFF Control (Option N)
Off-State Voltage
On-State Voltage
ON/OFF Control (Either Option)
ON/OFF Control Hysteresis
Pull-Up Voltage
Pull Up Resistance
Output Voltage Trim Range
Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
Min.
247.50
123.75
-2.0
4.0
4.0
-2
4.75
-50
113
Typ.
250.00
125.00
1.5
5.00
10
118
120
10
2.1
1.9
Max.
252.50
126.25
1.0
18
18
1.0
5.25
+5
123
Units Notes & Conditions
kHz Over sample, temp & life
kHz Over sample, temp & life
V
V
V
V
Figures A & B
V
V
kW
%
Measured across Pins 8 & 4; see trim section
%
Over full temp range; % of nominal Vout
°C Average PCB Temperature
°C
106 Hrs.
106 Hrs.
106 Hrs.
MTRI-LN-HWDBT-K0-0201373F;2;808%0%lolaoda,d,330000LLFFMM,,4400ooCCTTaa
See website for details
STANDARDS COMPLIANCE
Parameter P
STANDARDS COMPLIANCE
UL/cUL 60950-1
EN60950-1
72/23/EEC
93/68/EEC
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
Telcordia (Bellcore) GR-513
Notes
File # E194341, Basic insulation & pollution degree 2
Certified by TUV
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8kV - NP, 15kV air - NP (Normal Performance)
Section 7 - electrical safety, Section 9 - bonding/grounding
• An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety
certificates on new releases or download from the SynQor website.
QUALIFICATION TESTING
Parameter P
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
# Units Test Conditions
32
5
5
10
5
5
5
15 pins
95% rated Vin and load, units at derating point, 1000 hours
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axes
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off
MIL-STD-883, method 2003
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
robust, reliable product. Contact the factory for official product family qualification documents.
OPTIONS
SynQor provides various options for Pin Length and Feature Set
for this family of Power Interface Modules. Please consult the last
page for information on available options.
PATENTS
SynQor is protected under various patents. Please consult the
last page for further information.
Product # PQ60120HZA50
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2HZ612J Rev. A
8/20/07
Page 5