English
Language : 

PQ60033EKX15 Datasheet, PDF (5/15 Pages) SynQor Worldwide Headquarters – Eighth-brick DC-DC Converter
Technical Specification
Input: 35-75V
Output: 3.3V
Current: 15A
Part No.: PQ60033EKx15
PQ60033EKx15 ELECTRICAL CHARACTERISTICS (continued)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 48V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min. Typ. Max. Units Notes & Conditions
DYNAMIC CHARACTERISTICS
Input Voltage Ripple Rejection
Output Voltage during Load Current Transient
Step Change in Output Current (0.1A/µs)
Step Change in Output Current (5A/µs)
Settling time
Turn-On Transient
Turn-On Time
Start-Up Inhibit Time
180
Output Voltage Overshoot
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
Isolation Resistance
Isolation Capacitance (input to output)
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
Board Temperature
Transformer Temperature
FEATURE CHARACTERISTICS
Switching Frequency
270
ON/OFF Control (Option P)
Off-State Voltage
0
On-State Voltage
2
ON/OFF Control (Option N)
Off-State Voltage
2
On-State Voltage
0
ON/OFF Control (Either Option)
Pull-Up Voltage
Pull-Up Resistance
Output Voltage Trim Range
-10
Output Voltage Remote Sense Range
Output Over-Voltage Protection
120
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
98
240
130
600
22
200
0
2000
30
1000
300
5
10
130
125
10
2.5
1.1
dB 120Hz
See Note 3
mV 50% to 75% to 50% Iout max; Figure 11
mV 50% to 75% to 50% Iout max; Figure 12
µs To within 1% Vout nom
ms Full load, Vout=90% nom; Figures 9 & 10
240
ms -40°C to +125°C; Figure F
% Maximum Output Capacitance
V See Absolute Maximum Ratings
MΩ
pF See Note 4
125
°C Package rated to 150°C
125
°C UL rated max operating temp 130°C
125
°C
330
kHz
0.8
V
13.5
V
13.5
V
0.8
V
Application notes; Figures A & B
6
V
kΩ
10
% Measured across Pins 8 & 4; Figure C
10
% Measured across Pins 8 & 4
140
% Over Full Temperature Range; % of nominial Vout
°C Average PCB Temperature
°C
106 Hrs. TR-NWT-000332; 80% load, 300LFM, 40°C Ta
106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40°C Ta
106 Hrs. See our website for details
Note 1: The UVLO values represented here are typical of lighter load conditions. The unit may shut down under high load conditions before the typical
UVLO limits.
Note 2: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 3: The module requires a minimum amount of capacitance (100μF) in order to ride through a No Load to Full Load transient (0.1A/μs) without
shutdown.
Note 4: Higher values of isolation capacitance can be added external to the module.
Product # PQ60033EKx15
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005111 Rev. B
06/17/09
Page 5