English
Language : 

PQ65180QGA06 Datasheet, PDF (3/13 Pages) SynQor Worldwide Headquarters – 100 Watt, No Heatsink, Isolated DC/DC Converter
Technical Specification
Quarter
Brick
48Vin 18Vout 5.6A
PQ65180QGA06 ELECTRICAL CHARACTERISTICS
TA=25°C, airflow rate=300 LFM, Vin=48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient
temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Non-Operating
Operating
Operating Transient Protection
Isolation Voltage (input to output)
Operating Temperature
Storage Temperature
Voltage at ON/OFF input pin
INPUT CHARACTERISTICS
Operating Input Voltage Range
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Voltage Hysteresis
Maximum Input Current
No-Load Input Current
Disabled Input Current
Inrush Current Transient Rating
Response to Input Transient
Input Reflected Ripple Current
Input Terminal Ripple Current
Recommended Input Fuse
Input Filter Component Values (C\L)
Recommended External Input Capacitance
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise1
Peak-to-Peak
RMS
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
DYNAMIC CHARACTERISTICS
Input Voltage Ripple Rejection
Output Voltage During Load Current Transient
For a Step Change in Output Current (0.1A/µs)
For a Step Change in Output Current (5A/µs)
Settling Time
Turn-On Transient
Turn-On Time
Start-Up Inhibit Time
Output Voltage Overshoot
EFFICIENCY
100% Load
50% Load
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
Board Temperature
Transformer Temperature
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
Isolation Resistance
Isolation Capacitance2
Min.
-40
-55
-2
40
37
33.5
2.5
17.73
17.43
0
5.9
0.1
0
10
180
Typ. Max. Units Notes & Conditions
100
80
100
2000
100
125
18
V continuous
V continuous
V 100ms transient, square wave
V Basic insulation, Pollution Degree 2
°C
°C
V
48
75
V
38
34.5
3.5
80
1.6
600
4
60
2.46\4.7
47
39
35.5
4.5
3.0
120
3
0.04
20
V
V
V
A
mA
mA
A2s
mV
mA
mA
A
µF\µH
µF
100% Load, 40 Vin
1000V/ms input transient
P-P thru 10µH inductor; Figs. 13 & 15
RMS; Figs. 13 & 14
fast blow external fuse recommended
internal values, see Figure E
Typical ESR 0.1-0.2Ω, see Figure 13
18.00
18.27
+0.04 \ 7
+0.04 \ 7
+112
+0.2 \ 36
+0.2 \ 36
+300
18.57
50
120
15
30
5.6
6.7
7.7
10
0.3
0.6
10
50
2,000
V
%\mV
%\mV
mV
V
mV
mV
A
A
V
A
mA
µF
Factory pre-set with Sense(+), Sense(-) open
over sample, line, load, temperature & life
20MHz bandwidth; Fig. 13 & 16
Full Load, see Figures 13 & 16
Full Load, see Figures 13 & 16
Subject to thermal derating; Figs. 5-8
Output Voltage 10% Low; Figure 17
Negative current drawn from output
Negative current drawn from output
18Vout at 5.6A Resistive Load
70
dB 120 Hz; Fig. 20
250
mV 50% to 75% to 50% Iout max; Figure 11
250
mV 50% to 75% to 50% Iout max; Figure 12
800
µs to within 1% Vout nom
12
15
ms Full load, Vout=90% nom.; Figs. 9 & 10
200
240
ms -40°C to +125°C; Figure F
0
% 2,000 µF load capacitance, Iout = 0A
91.5
90.5
% Figures 1 - 4
% Figures 1 - 4
125
°C Package rated to 150°C
125
°C UL rated max operating temp 130°C
125
°C See Figures 5 - 8 for derating curves
2000
V
30
MΩ
470
pF
Note 1: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 2: Higher values of isolation capacitance can be added external to the module.
Product # PQ65180QGA06
Phone 1-888-567-9596
Doc.# 005-2QG581D Rev. B
9/14/04
Page 3