PQ65180QGA06 Datasheet, PDF (1/13 Pages) SynQor Worldwide Headquarters – 100 Watt, No Heatsink, Isolated DC/DC Converter | |||
|
Technical Specification *
Quarter
Brick
48Vin 18Vout 5.6A
100 Watt, No Heatsink, Isolated DC/DC Converter
The PQ65180QGA06 PowerQor⢠Giga quarter-
brick converter is a next-generation, board-mount-
able, isolated, fixed switching frequency DC/DC
converter that uses synchronous rectification to
achieve extremely high conversion efficiency. The
power dissipated by the converter is so low that a
heatsink is not required, which saves cost, weight,
height, and application effort. All of the power and
control components are mounted to the multi-layer
PCB substrate with high-yield surface mount tech-
nology. Since the PowerQor converter has no
explicit thermal interfaces, it is extremely reliable.
Operational Features
⢠Ultra-high efficiency, 91% at full rated load current
⢠Delivers up to 100 Watts of output power with mini-
mal derating - no heatsink required
⢠Wide input voltage range: 40V â 75V, with 100V
100ms input voltage transient capability
⢠Fixed frequency switching provides predictable EMI
performance
⢠No minimum load requirement means no preload
resistors required
Mechanical Features
⢠Industry standard quarter-brick pin-out configuration
⢠Industry standard size: 1.45â x 2.3â (36.8x58.4mm)
⢠Total height less than 0.40â (10.2mm), permits better
airflow and smaller card pitch
⢠Total weight: 1.2 oz. (34 grams)
⢠Flanged pins designed to permit surface mount sol-
dering (avoid wave solder) using FPiP technique
Control Features
⢠On/Off control referenced to input side (positive
and negative logic options are available)
⢠Remote sense for the output voltage compensates
for output distribution drops
⢠Output voltage trim permits custom voltages and
voltage margining
Product # PQ65180QGA06
Phone 1-888-567-9596
PQ65180QGA06 Module
Protection Features
⢠Input under-voltage lockout disables converter at
low input voltage conditions
⢠Output current limit and short circuit protection
protects converter and load from permanent damage
and consequent hazardous conditions
⢠Active back bias limit prevents damage to convert-
er from external load induced pre-bias
⢠Output over-voltage protection protects load from
damaging voltages
⢠Thermal shutdown protects converter from abnor-
mal environmental conditions
Safety Features
⢠2000V, 30 M⦠input-to-output isolation provides
input/output ground separation
⢠UL/cUL 60950 recognized (US & Canada), basic
insulation rating
⢠TUV certified to EN60950
⢠Meets 72/23/EEC and 93/68/EEC directives
which facilitates CE Marking in userâs end product
⢠Board and plastic components meet UL94V-0 flam-
mability requirements
* Final datasheet pending ECO review and signature.
Doc.# 005-2QG581D Rev. B
9/14/04
Page 1
|
▷ |