MCOTS-F-28-T-HT Datasheet, PDF (13/14 Pages) SynQor Worldwide Headquarters – Standby circuitry to minimize quiescent power draw | |||
|
◁ |
Technical Specification
MCOTS-F-28-T-HT
Current: 30A
Mil-COTS Qualification
Test Name
Details
# Tested
(# Failed)
Consistent with
MIL-STD-883F Method
Life Testing
Shock-Vibration
Humidity
Temperature
Cycling
Solderability
DMT
Altitude
Visual, mechanical and electrical testing before, during and
15
after 1000 hour burn-in @ full load
(0)
Visual, mechanical and electrical testing before, during and
5
after shock and vibration tests
(0)
+85 ËC, 95% RH, 1000 hours, 2 minutes on / 6 hours off
8
(0)
500 cycles of -55 ËC to +100 ËC
10
(30 minute dwell at each temperature)
(0)
15 pins
15
(0)
-65 ËC to +110 ËC across full line and load specifications in
7
5 ËC steps
(0)
70,000 feet (21 km), see Note
2
(0)
Method 1005.8
MIL-STD-202,
Methods 201A & 213B
Method 1004.7
Method 1010.8, Condition A
Method 2003
Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres.
Screening
Baseplate Operating
Temperature
Storage Temperature
Pre-Cap Inspection
Temperature Cycling
Burn-In
Final Electrical Test
Final Visual Inspection
Mil-COTS Converter and Filter Screening
Process Description
S-Grade
IPC-A-610, Class III
MIL-STD-883F, Method 1010, Condition B, 10 Cycles
100 ËC Baseplate
100%
MIL-STD-883F, Method 2009
-55 ËC to +100 ËC
-65 ËC to +135 ËC
â
12 Hours
25 ËC
â
M-Grade
-55 ËC to +100 ËC
-65 ËC to +135 ËC
â
â
96 Hours
-55 ËC, +25 ËC, +100 ËC
â
STANDARDS COMPLIANCE
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
UL 60950-1
Basic Insulation
CAN/CSA C22.2 No. 60950-1
EN 60950-1
Note: An external input fuse must always be used to meet these safety requirements.